Basket07399 358543
Steel locker plans

Plans/Home/Steel locker

Steel locker plans

A steel locker built from flat sheet: 2 mm sheet welded to a light box-section frame, full-height doors on weld-on hinges, a shelf and a hanging rail. Drawn with 1, 2 or 3 doors.

£5The total, all 3 sizes. No VAT added, no other fees.
Add to basket – £5
  • Any 3 plans £12, any 5 £18Mix and match from any category: the basket works out the cheapest way.
  • Home bundle: all 35 furniture plans £15£171 one by one. Every size of every plan.Add the bundle
  • All Access: every plan £39All 134 plans now, and every new plan for 12 months.Add All Access

At checkout you tick that you want the download to start now, and that you then lose the 14-day right to cancel. If a file is faulty or not as described here, we put it right or refund you.

3 sizes, 10 A4 pages each, a DXF for every plate.Every part taken off a 3D model and checked before it is drawn. Licence and terms.

Drawn by a former fabricator and CSWIP 3.1 welding inspector.

Three sizes, one price

Each size is its own plan: its own cutting list, part drawings, DXFs and checks. Pick the one that fits your kit, or build more than one.

2-door1-door3-door
Overall604 x 457 x 1802 mmacross x front to back x high304 x 457 x 1802 mmacross x front to back x high904 x 457 x 1802 mmacross x front to back x high
Steel in it115 kg69 kg162 kg
Steel to buy140 kgabout £420 at £3 a kg, in whole stock bars: a stockist who cuts to length charges for less88 kgabout £260 at £3 a kg, in whole stock bars: a stockist who cuts to length charges for less197 kgabout £590 at £3 a kg, in whole stock bars: a stockist who cuts to length charges for less
Basisa calculation check against the EN 16121 / EN 14749 storage loads, not a physical testa calculation check against the EN 16121 / EN 14749 storage loads, not a physical testa calculation check against the EN 16121 / EN 14749 storage loads, not a physical test
Shelves8 kg on each shelf and floor, spread8 kg on each shelf and floor, spread8 kg on each shelf and floor, spread
Doors300 N down on an open door's corner300 N down on an open door's corner300 N down on an open door's corner
Top750 N on the top750 N on the top750 N on the top
Fixingscrewed to a solid wall at the topscrewed to a solid wall at the topscrewed to a solid wall at the top
Sheet2 mm steel sheet throughout: flat sheet only, no press brake2 mm steel sheet throughout: flat sheet only, no press brake2 mm steel sheet throughout: flat sheet only, no press brake

Swipe the table sideways to see every size.

What is in the plan

10 A4 pages a size that print at home, every page taken off the 3D model, and a 1:1 DXF of every plate.

  1. Cover and limitsWhat it is, what it carries, what it is not for, and the safety basics.
  2. What you needWhole stock bars to buy (already nested), plates, castors and fixings, tools, a steel cost.
  3. Cutting listEvery piece by its letter: section, length, the cut at each end, how many.
  4. Bar plansHow each stock bar is cut up, so nothing is wasted and nothing is short.
  5. General arrangementFront, side, plan and 3D with the main sizes.
  6. Every part drawnEach bar with its length and end cuts, each plate with its holes set out.
  7. Build stepsThe model at each step with the new parts in orange, and what to do.
  8. DXF filesA 1:1 cutting file for every plate, ready for laser, plasma or water-jet.

Before you buy

Plans for a hobby build in a home workshop, not a certified design. What it carries and what it is not for are listed here and on page 1 of the plan.

Good for

  • A gym, a workshop or a boot room
  • Kit, tools or sports gear
  • Locked with a cam lock in each door

Not for

  • Climbing it or hanging on a door
  • Leaving it unfixed: screw it to the wall
  • Locking anyone or any animal in it

The build

SkillConfident welder: thin sheet without burning through, square cuts, drill
Time10 to 16 hours
Pieces6 bar marks, 6 plates
Steps5

Tools

  • MIG welder (0.6 mm wire for the sheet)
  • Angle grinder with cutting, flap and thin cutting discs
  • Chop saw or bandsaw
  • Jigsaw or plasma for the sheet (or have it guillotined)
  • Drill, HSS bits, a step drill
  • Tape, square, clamps, magnets

Degrease, prime and paint, or powder coat; paint the inside too.

What it was drawn for

The standard size. Each size's own figures are in the table above and on page 1 and the last page of its plan.

  • Basis: a calculation check against the EN 16121 / EN 14749 storage loads, not a physical test
  • Shelves: 8 kg on each shelf and floor, spread
  • Doors: 300 N down on an open door's corner
  • Top: 750 N on the top
  • Fixing: screwed to a solid wall at the top
  • Sheet: 2 mm steel sheet throughout: flat sheet only, no press brake

The checks we ran

  • Shelf (EN 14749 / EN 16121): 2 mm plate over 425: bending 12 % of its strength at 1.5 x load, sags 1.9 mm (limit 4.2)
  • Top: 2 mm plate over 125: bending 64 % of its strength at 1.5 x load, sags 0.7 mm (limit 1.2)
  • Shelf rails: SHS 25x25x2.5 over 275: bending 1 % of its strength at 1.5 x load, sags 0.0 mm (limit 1.4)
  • Door on its hinges (EN 16121): 300 N down on the open door's free corner (EN 16121 5.7.1.5) and its own weight: 0.1 kN pulls the top hinge at 1.5 x, 34.7 kN it takes
  • Door stiffening: a FL 25x3 stiffener ring on every door: the sheet spans 240 between its sides
  • Posts: SHS 25x25x2.5 300 long in compression: 1 % of its buckling strength at 1.5 x load
  • Wall tie: with a door open and 100 N pulled at the top it relies on the wall fixings through the back (1.4 times what holds it alone): drawn, and must be fixed (house rule: storage 686 mm high and over)

Do not

  • Do not climb it or hang on an open door.
  • Do not leave it unfixed: tie it to the wall.
  • Do not lock a child or an animal in it: it is for things, not people.

The licence

Short version. The full licence is in every plan and on the licence page.

  • Build as many as you like, for yourself or to sell (you are the maker of what you sell).
  • Change the build for your own use.
  • Do not copy, share, post or resell the files, or sell plans made from them.
  • One licence is for one buyer.

Questions

Do I need a press brake?

No. Every sheet is flat: sides, back, top, floors, shelves and doors are welded to the tube frame, and each door is stiffened by a flat bar ring.

What loads is it drawn for?

The EN 16121 storage figures: 300 N down on an open door's corner, 750 N on the top and 0.65 kg/dm2 on each shelf.

What do I download?

One zip: the plan in every size as an A4 PDF that prints at home, a 1:1 DXF of every plate for laser, plasma or water-jet cutting, and the licence. Nothing to install, no account.

Can I sell what I build?

Yes. The plan licence lets you build and sell the items. You are then the maker, responsible for their safety and for the rules that apply where you sell them. Lifting gear and powered gates are machinery in law: selling one, or putting one to work, needs a declaration of conformity and UKCA marking first, as their pages say. What you cannot do is share or sell the plans themselves.

Can I get a refund?

Plans are a download. At checkout you ask for the download to start straight away and confirm you then lose the 14-day right to cancel, as the plan terms set out. If a file is faulty or is not what this page describes, we put it right or refund you.

Is it an engineered design?

No. It is a set of plans for a hobby build, drawn and checked by us for the loads and limits listed on the page and in the plan. It is not a structural calculation or a certified design.

Can I have a different size?

Yes. Every plan is a 3D model: send us the sizes you want and we redraw it, re-run its checks and send the new plan.

Are the sizes metric?

All sizes are in millimetres. The steel is UK and European stock: box section to BS EN 10219, flat and round bar, plate by thickness.

Steel locker plans, all 3 sizes, £5.

Add to basket

Need another size? Send us your sizes and we redraw it.

£5 all 3 sizesAdd