Guides/Driveway gate height, opening and automation
Driveway gates: height, opening and automation rules
Three rules decide most driveway gate jobs in England: how tall the gate may be without planning permission, which way it may open, and what makes an automated gate safe. This guide covers each in turn and says what to check with your council.

Height without planning permission
Gates, fences and walls fall under Part 2, Class A of the General Permitted Development Order 2015. A new gate or a replacement may not be more than 1 metre above ground level where it is next to a highway used by vehicular traffic, and not more than 2 metres above ground level in any other case. The height is measured from the ground to the top of the highest part, finials and arches included.
A driveway gate on the road frontage is almost always next to a highway, so 1 metre is the figure that applies. A taller gate set back behind a fence or hedge is not next to the highway in the same way, but the council decides what counts as next to. Gates at the side or rear of a house usually come under 2 metres.
The rights do not apply within the curtilage of a listed building, and an Article 4 direction can remove them for a street or a conservation area. Many houses with a bow-top pair at 1.8 m are built under a planning permission or have been there for years. Ask the council before you order a tall gate at the front.
| Item | Figure | Source |
|---|---|---|
| Gate next to a highway used by vehicles | 1 m maximum without planning | GPDO 2015 Sch 2 Part 2 Class A |
| Gate elsewhere | 2 m maximum without planning | GPDO 2015 Sch 2 Part 2 Class A |
| Gate on premises opening on a street | Must not open outwards | Highways Act 1980 s.153 |
| Powered gate: finger, hand, arm gaps | 25, 100, 120 mm | DHF TS 013-1 |
| Hinge gap on a powered gate | Under 4 mm or over 25 mm | DHF TS 013-1 |
Swipe the table sideways to see every column.
Which way a gate may open
Section 153 of the Highways Act 1980 says a door, gate or bar on premises opening on to a street shall be so put up as not to open outwards. A gate that swings out over the footway is an obstruction and the highway authority can serve a notice. A new vehicle access across the footway also needs the highway authority's consent for the dropped kerb (section 184 of the same Act), and planning permission where the road is classified. Failing to act within 8 days of the notice is an offence with a fine up to level 1 on the standard scale.
So a pair of driveway gates opens inwards, into the property, and there has to be room for the leaves to swing without hitting a parked car. We draw the swing arcs on the plan and the clearance to the fence, the pier and the house. A sliding gate has no arc, but it needs a straight run of fence for the leaf to slide along, roughly the opening width plus a tail.
Posts, piers and hinges
A gate leaf is heavy, and the posts carry it. Brick piers need a steel core or a post set into the ground in concrete, and the hinges must be rated for the weight. Our drawings show the hinge type, the post section, the foundation size you give us and the gap at each hinge. Your engineer or supplier checks the post and footing for the leaf weight and wind.
Wind matters more than people expect. A solid or close-boarded leaf acts like a sail. DHF TS 013-1 treats a gate with more than 30% infill as having considerable wind resistance, which affects the size of the hinges, the posts and any motor.
Automation: the installer's duty
A motor on a driveway gate turns it into a powered machine. The trade code of practice, DHF TS 013-1, says the compliance assessment must consider hazards from normal use and foreseeable misuse, and gives the example of people walking through vehicle entrances. Where the assessment of a bought-in UKCA or CE marked system shows residual hazards because of its local environment or use, it says the installation company should address them.
In plain terms, the installer is responsible for the finished gate being safe, not only the motor box. That covers crush and shear points along the leaf and at the hinge, safe edges, force limits and presence detection. The code lists the gaps that avoid injury: finger 25 mm, hand or wrist 100 mm, arm or foot 120 mm, leg 180 mm. For the hinge side it says to design the gap to be under 4 mm or over 25 mm and constant.
We draw the gate so that the gaps can be made safe: hinge-side clearances, space for safe edges on the leaf and room for the operator. We do not choose the motor, set the forces or sign the installation off.
Choosing manual or automated
Manual gates are cheaper and have fewer things to go wrong, but a pair of heavy leaves is a nuisance in the rain. If you may automate later, tell us now. We can leave room for the operator, run cable ducts through the piers and fit three hinges on the swing leaf, which Gate Safe, a UK gate safety charity, recommends for swing gates. A 24 V system with a battery back-up keeps working in a power cut.
A pedestrian gate beside the main gate is worth adding. It means nobody has to open the big leaves to get through, and the code of practice names people walking through pedestrian entrances as foreseeable misuse.
Questions
How high can a driveway gate be without planning permission?
1 metre next to a road used by vehicles and 2 metres elsewhere, including finials and arches (GPDO 2015, Part 2, Class A). Listed buildings and Article 4 areas are excluded. Check with your council.
Can driveway gates open onto the road?
No. Section 153 of the Highways Act 1980 says a gate on premises opening on a street must be put up so that it does not open outwards. Fit them to open inwards.
Who is responsible for the safety of an automated gate?
The installer assesses and signs off the gate as installed. The trade code of practice expects them to address hazards from the local environment or use. We draw the gate; we do not certify it.
Do automated gates need a pedestrian gate?
We recommend one. The code of practice names people walking through entrances and riding on moving gates as foreseeable misuse. A separate pedestrian gate gives people a safe way through. The installer decides what the assessment needs.
Do I need three hinges on a swing gate?
The charity Gate Safe recommends three hinges on swing gates or a tether to stop a leaf falling if a hinge fails. It is a recommendation, not a rule, and we draw three where the leaf is heavy.
What do you need to draw a gate?
The opening width, the heights at each post, the ground levels, photographs, the distance to the road, and whether the gates will be automated. Your measurements decide the swing.
Sources
Read on the published page. These guides are for England unless they say otherwise, and explain the documents: your council, building control body and engineer decide your job.
- The Town and Country Planning (General Permitted Development) (England) Order 2015, Schedule 2 Part 2, Class A, A.1(a)(ii)“in any other case, 1 metre above ground level”
- The Town and Country Planning (General Permitted Development) (England) Order 2015, Schedule 2 Part 2, Class A, A.1(b)“would exceed 2 metres above ground level”
- Highways Act 1980, section 153, s.153(1)“shall be so put up as not to open outwards”
- DHF TS 013-1:2021 Code of practice for automated gates, traffic barriers, industrial and garage doors, Part 1 (v4), Compliance assessment“Foreseeable misuse includes people walking through or under vehicle entrances”
- DHF TS 013-1:2021 Code of practice for automated gates, traffic barriers, industrial and garage doors, Part 1 (v4), Safe distances table“Finger = 25mm”
- DHF TS 013-1:2021 Code of practice for automated gates, traffic barriers, industrial and garage doors, Part 1 (v4), Hinge area“a constant gap of less than 4mm or more than 25mm”
Where next

Driveway gates
Driveway, side and pedestrian gates, manual or automated, on piers or posts.
From £99back in 3 working days

Gates, railings and fencing
Bow-top and flat-top driveway gates, garden gates, railings on walls, sliding and automated gates, and security fencing, drawn with the hinges, the hardware and the foundations.
9 typessee them all
More guides

Balustrade heights in the UK
Balustrade height rules for England: 900 mm on stairs, 1100 mm on external balconies in houses, and the 100 mm sphere test for every gap and opening.
Guide5 sources read

Juliet balcony rules in England
Juliet balcony rules for England: a guard at least 1100 mm high, a 100 mm sphere test, no platform to stand on and fixings that suit the wall.
Guide5 sources read

Do you need planning for a carport or canopy?
Planning for a carport, canopy or pergola in England: a porch is limited to 3 m2, and an outbuilding to 2.5 m high within 2 m of a boundary.
Guide6 sources read