Basket07399 358543

Guides/Balustrade heights in the UK

Balustrade heights in the UK

In England, Approved Document K sets the minimum height of guarding by building type and by where it stands. This guide sets out the heights, the 100 mm gap rule and the difference between a handrail and guarding, so you can check a quote or a drawing before you order.

Balustrade heights in the UK

Which document sets the height

For England the rule is Approved Document K (Protection from falling, collision and impact), 2013 edition. It is the guidance Building Control works from. Wales has its own version and Scotland uses its Technical Handbooks, so the figures below are for England only. If your job is outside England, check the local document before you order anything.

Diagram 3.1 in the document gives a minimum height for each building category and location. Paragraph 1.38 sends stair guarding to the same diagram. The heights are minimums, measured from the surface a person walks on or from the pitch line on a stair. A taller guard is allowed. A shorter one is not.

Minimum guarding height in England, Approved Document K Diagram 3.1 (mm)
LocationSingle family dwellingFlats, offices, schools, public buildings
Stair flight900900
Landing9001100
Edge of internal floor9001100
External balcony or Juliet balcony11001100
Edge of roof11001100
Opening window800800

Swipe the table sideways to see every column.

The heights, by building and location

In a single family dwelling, guarding to stairs, landings, ramps and the edges of internal floors is 900 mm. External balconies, including Juliet balconies, and the edges of roofs are 1100 mm. At an opening window the guard height is 800 mm.

In flats, offices, schools and other public buildings the stair flight is still 900 mm, but landings and the edges of floors are 1100 mm. The table above puts the main figures side by side. Check which category your building falls into before you pick a row, because a house converted into flats changes category.

When guarding is needed at all

In a dwelling, guarding is needed at the sides of flights and landings when there is a drop of more than 600 mm (paragraph 1.41). In flats and other buildings, paragraph 1.40 asks for guarding at the sides of flights and landings with two or more risers. A balcony, a roof terrace and a window opening onto a drop each need their own check.

Building Control often looks hard at the odd places: the edge of a mezzanine, a sunken area, a low terrace beside a path, a stair going down to a basement. If a person can fall from it, plan for guarding.

The 100 mm sphere and climbing

In a building that may be used by children under five, a 100 mm sphere must not pass through any opening in the guarding (paragraph 3.3a for guarding, 1.39a for stair flights). That applies to every gap: between bars, between a bar and a post, under the bottom rail and along the line of a stair's nosings.

We check this on the model rather than by eye. A bottom rail that sits 120 mm off the floor fails, and so does a gap beside a stair that opens up as the steps rise. The fix is usually to lower the rail or add a short bar. It costs nothing if it is found on the drawing instead of on site.

The same paragraph says to prevent children readily climbing the guarding, and to avoid horizontal rails. AD K gives no dimension for a toe-hold. Horizontal bars, wire and cable look neat, but they are the first thing a building inspector queries on a house or a block of flats. Vertical bars, glass and solid panels avoid the question.

Handrail or guarding

A handrail is something to hold. On a stair its top sits 900 mm to 1000 mm above the pitch line or floor (paragraph 1.34a), and a stair 1000 mm or wider needs one on both sides (1.34c). A handrail may form the top of the guarding if the heights match (1.34b). On a stair guarded at 900 mm that is easy. On a balcony guarded at 1100 mm, the handrail is usually a separate rail on the wall.

Where a raked stair meets a landing guarded at 1100 mm, the rail has to climb or the guard has to change height. We draw the stair rail as one straight run on the pitch and show the height where it meets the landing, so the fabricator is not left to bend a kink in on site.

Drawing the join early also settles where the posts go. A post cannot stand in the middle of a landing turn, so we set the posts out from the nosings and the corners first, then fit the rail to them. It saves arguments on site about why the rail has a joint where it has.

Loads, glass and what we do not decide

Guarding must resist the barrier loads in BS EN 1991-1-1 and its UK National Annex, with PD 6688-1-1 (paragraph 3.2c). The load depends on where the guarding is and who uses it. The sizes of posts, glass and fixings that carry that load come from your engineer or your supplier's tested system. We are a drawing office: we draw the design you give us and check heights and gaps. We do not calculate the loads.

Where glass is part of the guarding, AD K also refers you to its glazing section (paragraph 3.2d). Fixings matter as much as the infill. A post bolted close to a slab edge or into thin concrete will not hold the load whatever the sheet says. Send us the slab edge and the build-up, and we draw the fixing against them.

Questions

How high does a balcony balustrade have to be?

In England the minimum is 1100 mm above the floor you stand on, including Juliet balconies on a house (Approved Document K, Diagram 3.1). If there is a step or toe-hold beside the guard, ask your engineer where the height is measured from.

What height is a stair balustrade in a house?

900 mm on the flight, measured from the pitch line, and 900 mm on the landing in a single family dwelling. In flats and other buildings the landing guard is 1100 mm. The handrail on the stair sits 900 mm to 1000 mm above the pitch line.

What is the 100 mm rule?

A 100 mm sphere must not pass through any opening in the guarding where children under five may use the building. It applies to gaps between bars, under the bottom rail and along a stair's nosing line. We check every gap on the model before drawings go out.

Can I use horizontal bars or wire?

AD K says to avoid horizontal rails on guarding where children may climb it. It is guidance rather than a ban, but inspectors query it on houses and flats. Vertical bars or glass are the safer choice.

Is a handrail the same as a balustrade?

No. A handrail is held by hand and sits 900 mm to 1000 mm above the pitch line on a stair. Guarding stops a fall and is 900 mm to 1100 mm depending on the place. The handrail can form the top of the guarding if the heights match.

Do the rules differ in Scotland and Wales?

Yes. This guide covers England and Approved Document K. Wales and Scotland use their own documents. Check with your local building control before you order.

Sources

Read on the published page. These guides are for England unless they say otherwise, and explain the documents: your council, building control body and engineer decide your job.

  1. Approved Document K: Protection from falling, collision and impact, 2013 edition (England), Diagram 3.1, p.24“External balconies, including Juliette balconies and edges of roof”
  2. Approved Document K: Protection from falling, collision and impact, 2013 edition (England), para 3.3a, p.24“ensure that a 100mm sphere cannot pass through any openings in the guarding”
  3. Approved Document K: Protection from falling, collision and impact, 2013 edition (England), para 1.41, p.17“when there is a drop of more than 600mm”
  4. Approved Document K: Protection from falling, collision and impact, 2013 edition (England), para 1.34a, p.14“the top of the handrail 900mm to 1000mm from the pitch line”
  5. Approved Document K: Protection from falling, collision and impact, 2013 edition (England), para 3.3b, p.24“avoid horizontal rails”