The four sizes
As on the railings pack. Letters match the sketch.
- ALength of each run
- BHeight of the wall
- CHeight of the piers
- DWidth of the wall top
The four sizes, and where the tape goes
A is the length of each run. A run is a stretch of railing between two fixed points: a pier, a house wall, a gate or a change of direction. Measure each run on its own, along the top of the wall, from the face of one pier to the face of the next. Do not measure the whole frontage in one go and divide. Walls drift out of line, and the last panel then comes out short. Write the runs down in order from the left as you face the house from the road.
B is the height of the wall. Measure from the pavement or ground on the outside to the top of the wall, at both ends of each run, because a frontage often steps with the street. If the wall is on a slope, measure the height at each pier. The railing is then drawn to rake or to step, whichever you prefer.
C is the height of the piers. Measure from the same ground to the top of the cap, not the pier shaft. A cap that overhangs its shaft changes the clear space between piers, so measure the gap between the shafts and between the caps and send both.
D is the width of the wall top: the flat surface the railing stands on. Measure across it at several places, because old brick walls vary. This decides whether the posts sit on top of the wall, are fixed to its face, or are cored into it.
| Measure | From / to | Why we need it |
|---|---|---|
| A: length of each run | Face of one pier or end to the next, along the wall top | Sets the panel widths and the bar spacing |
| B: height of the wall | Outside ground to the wall top, at both ends of each run | Sets the railing height and any rake or step |
| C: height of the piers | Outside ground to the top of the cap; gap between shafts and between caps | Sets the panel height between piers |
| D: width of the wall top | Across the flat top, several places | Decides how the posts fix |
| Distance to the road | Wall face to the edge of the carriageway | Decides the 1 m or 2 m height limit |
| Gate details | Height, bar spacing, hinge position | So the railings match the gate |
| Steps in the wall | Each step: where, and how high | Decides rake or step in the railing |
Swipe the table sideways to see every column.
The six photos
Take the frontage from the street, standing back so the whole length is in view. Then photograph the wall along its length from inside the garden, which shows the condition of the brick, the coping and the line of the top.
Photograph each pier or end close up: the cap, the shaft, how it meets the wall and any gate hinge or latch fixings on it. Photograph the top of the wall, straight down, with a tape across it for width. Last, anything in the way: a tree root pushing the wall, a lamp, a meter box, a gate that opens over it.
For matching a gate, photograph the gate too, and measure its height and the spacing of its bars. We copy the spacing so the new railings and the existing gate look like one set.
Levels and steps
Measure the fall of the wall top by stretching a string between the end piers and levelling it with a line level or a long spirit level. Then measure from the string down to the wall top at each pier. The differences show how the top steps or rakes. If the wall steps in blocks, note each step and where it is. Write down the distance between each pair of readings.
Heights and boundaries that matter
Height rules for a wall or railing on a house frontage come from Part 2, Class A of the General Permitted Development Order. A gate, fence, wall or other means of enclosure next to a highway used by vehicles must not exceed 1 metre above ground level, and elsewhere must not exceed 2 metres. The height is taken to the top of the highest part, so measure to the top of any finial, not just the top rail.
Measure the distance from the wall to the road edge and say whether the road is a highway used by vehicles. The rights do not apply at a listed building, and in a conservation area or under an Article 4 direction they may be removed. Ask the council if you are unsure.
What not to measure
Do not measure bar spacing, rail sizes or fixing depths. We work these out from the height and the gap rule, and we check the 100 mm gap on the model. If you want a particular bar spacing to match a gate or an old pattern, send a photo with a tape against it.
What happens after you send it
We check the sizes and photos first. If a run does not add up, for example the runs come to more than the whole frontage you measured, we reply within one working day and say so. The railings are then drawn on one 3D model of your frontage, with the elevation set out between piers and the bar and cut list for a fabricator.
Questions
How high can railings be on a front wall?
Under Part 2, Class A of the General Permitted Development Order, a gate, fence, wall or other enclosure next to a highway used by vehicles must not exceed 1 metre above ground level, and elsewhere 2 metres. The wall and railing count together. Listed buildings and Article 4 areas are different.
Do I measure the wall or the piers?
Both. Measure the run from pier face to pier face along the wall top, and the height of the wall and the piers from the ground outside. Send the width of the wall top too. Measure the caps and the shafts separately, because the cap often overhangs.
What if my wall is not level?
Stretch a string between the end piers, level it, and measure from the string down to the wall top at each pier. Send the readings and the distances between them. We draw the railings to rake with the wall, or to step, as you prefer.
Do I need to match my existing gate?
It helps to. Send a photo of the gate with a tape against it, and its height and bar spacing. We copy the spacing and the top detail so the railings and the gate read as one set. If the gate is being replaced too, tell us, and we draw both together.
How accurate do the measurements need to be?
Careful tape readings are enough for the pack. Walls move over the years and ivy hides the real top, so your figures are the starting point. The fabricator takes final sizes from the wall itself, and a site measure before cutting is normal practice.
Sources
Read on the published page. These guides are for England unless they say otherwise, and explain the documents: your council, building control body and engineer decide your job.
- The Town and Country Planning (General Permitted Development) (England) Order 2015, Schedule 2, Part 2, Class A, A.1(a)(ii)“in any other case, 1 metre above ground level”
- The Town and Country Planning (General Permitted Development) (England) Order 2015, Schedule 2, Part 2, Class A, A.1(b)“would exceed 2 metres above ground level”
- JPA Design: Railings design pack, What we need from you“Length of each run”
Where next

Railings
Railings on walls and garden railings, matching your gates.
From £99back in 3 working days

Gates, railings and fencing
Bow-top and flat-top driveway gates, garden gates, railings on walls, sliding and automated gates, and security fencing, drawn with the hinges, the hardware and the foundations.
9 typessee them all

Driveway gate height, opening and automation
Driveway gate rules in England: 1 m high next to a road and 2 m elsewhere without planning, gates must not open outwards, powered gates need safe gaps.
Guide6 sources read

Railings on walls
Steel railings on dwarf walls between brick piers, matching the gates.
From £179design pack
More guides

Balustrade heights in the UK
Balustrade height rules for England: 900 mm on stairs, 1100 mm on external balconies in houses, and the 100 mm sphere test for every gap and opening.
Guide5 sources read

Juliet balcony rules in England
Juliet balcony rules for England: a guard at least 1100 mm high, a 100 mm sphere test, no platform to stand on and fixings that suit the wall.
Guide5 sources read

Do you need planning for a carport or canopy?
Planning for a carport, canopy or pergola in England: a porch is limited to 3 m2, and an outbuilding to 2.5 m high within 2 m of a boundary.
Guide6 sources read