Basket07399 358543

Homes and gardens/Handrails/Handrails on posts

Handrails for steps and ramps

A handrail on its own posts beside external steps and ramps, where there is no wall to fix to, run on past the top and bottom.

Handrails for steps and ramps

3D modelRendered from the model we draw from.

What it is

Where steps or a ramp have no wall beside them, the handrail goes on posts, core drilled or base plated into the ground. The rail is continuous, extends beyond the top and bottom so you hold it before the first step, and turns down or returns at the ends.

If the drop beside the steps is high enough to need guarding, we draw the guarding under the rail too.

Sizes and options

As we draw it. Every size is set to your job.

PostsSHS 50 or CHS, core drilled or base plated
RailCHS 48.3 on saddles
Extensions300 mm past the top and bottom

Worth knowing

House steps need a handrail that runs on 300 mm.

Approved Document K gives no extension for a dwelling, but Approved Document M volume 1 asks for a handrail on a dwelling's external stepped approach that goes 300 mm beyond the top and bottom nosings, at 850 to 1000 mm above the pitch line. Our 900 to 1000 mm height satisfies both documents.

Source: Approved Document M volume 1 (2015 edition with 2016 amendments), paragraph 1.8f

The detail

How it is made, fitted and priced, and what to tell us.

With no wall to fix to, the rail stands on its own posts. Posts are either core drilled into the step or ramp edge, or sit on base plates bolted down, and the rail is continuous over the posts and run on beyond the ends of the steps or ramp. We set the posts out from the nosings so they land mid-tread and not on a nosing, and so the rail stays at the same height over the pitch line from the first step to the last.

Which ground fixing is allowed depends on what the steps are made of. Core drilling needs sound concrete around the hole and a set-back of about 125 mm from the edge; a base plate needs a flat step with room for the plate and the anchors; both need the edge distances for the anchor in use. Precast steps, in-situ concrete, and brick with paving slabs behave differently. Tell us the construction, and if it is paving over a bed, what is under it.

Heights: we use 900 to 1000 mm over the pitch line because that satisfies Approved Document K, Approved Document M volume 1 (850 to 1000 mm) and volume 2 (900 to 1000 mm) together. Ramps are different. In a dwelling or the common area of a flat block, ramps of 600 mm rise or less need no handrail, and the top of the rail is 900 to 1000 mm above the ramp surface (Approved Document K 2.12). In other buildings there is a rail on both sides, and a kerb of at least 100 mm on the open side.

A rail on its own posts is not guarding. If the drop beside the steps is over 600 mm at a house, Approved Document K 1.41 asks for guarding at the side of the flight, and a handrail on posts does not replace it. We check the drop on every run and draw guarding under the rail when it is needed. Price is low for a short flight and rises with the number of posts and the ground fixing: core drilling costs a coring visit, a base plate costs anchors and a flat surface.

More views

Renders and sheets from our sample projects: made-up jobs, modelled and drawn the way a real one is.

Handrails on posts - view 1, rendered from the 3D model
3D renderA real 3D model

Is it right for you?

Good for

  • Front steps and garden steps
  • Ramps to doors

Not for

  • Steps where there is a high drop beside them: guarding is needed under or beside the rail
  • Paving laid on a loose bed, where a core hole has nothing sound to bite into

What the drawings show

  • An elevation of the steps or ramp with the rail height over the pitch line, the post positions and the run-on at each end
  • The post fixing in section: core hole or base plate, with its depth and edge distance
  • The rail ends, returned or turned down, and the extension past the first and last step
  • The drop beside the steps checked against the guarding trigger, with a note where guarding is needed
  • A post schedule with the heights above the ground

Questions

Guide: How to measure for a handrail

Do outside steps need a handrail?

Where a new house has a stepped approach, Approved Document M volume 1 1.8 asks for a handrail on one side of any flight of three or more risers. Approved Document K sets the 900 to 1000 mm height. Other buildings follow Approved Document M volume 2 1.37. A rail on each side is needed on wider flights in those buildings.

How far past the last step does the handrail go?

At least 300 mm beyond the top and bottom nosings. Approved Document M volume 1 1.8f states it for a dwelling's stepped approach, and Approved Document M volume 2 1.37d and Approved Document K Diagram 1.12 give the same 300 mm for other buildings.

Do ramps need handrails?

Ramps of 600 mm rise or less in dwellings and the common parts of flats do not. Above that, a ramp 1000 mm or wider needs a handrail each side (Approved Document K 2.12). In other buildings, both sides are needed.

Is a handrail on posts enough where there is a drop?

No. At a house, a drop of more than 600 mm at the side of the steps needs guarding as well, under Approved Document K 1.41. A rail on posts does not replace it. We check the drop on every run and draw guarding under the rail where it is needed.

How are the posts fixed into the ground?

Either core drilled into the concrete or bolted down on a base plate. Which is allowed depends on the construction of the steps and on the anchor edge distances. Send us the step construction and the edge detail, and we say which fixing fits.

Your handrails on posts, drawn from a real 3D model.

Handrail design pack: from £99

Back in 3 working days or your money back. Or call 07399 358543 to ask first.