A round handrail on brackets fixed to the wall, continuous up the stair and round the landings, at the right height over every flight.

3D modelRendered from the model we draw from.
What it is
A wall handrail goes on brackets at no more than about 1 m centres, set so the rail sits 900 to 1000 mm above the pitch line. Where it runs on to a landing it rises with the landing; at the ends it returns to the wall so sleeves cannot catch.
On a stair 1 m wide or more there is a handrail both sides: a wall handrail on one side and the balustrade on the other.
Sizes and options
As we draw it. Every size is set to your job.
| Rail | CHS 42.4 or 48.3 |
| Brackets | Circle-plate wall brackets at up to 1000 mm |
| Height | 900 to 1000 mm over the pitch line |
Worth knowing
A stair 1 m wide needs a handrail both sides.
On a stair 1000 mm wide or more, there should be a handrail on both sides; narrower stairs need one. The rail goes 900 to 1000 mm above the pitch line.
Source: Approved Document K, 2013 edition, paragraph 1.34
The detail
How it is made, fitted and priced, and what to tell us.
The rail has to be a shape a hand can close round. Approved Document K Diagram 1.13 allows a circular rail of 32 to 50 mm diameter, set 50 to 75 mm off the wall, with at least 50 mm clear under a cranked support. A 42.4 or 48.3 mm tube meets that. A 60.3 mm tube does not. We draw the bracket projection to hold the clear gap to the wall, and the rail ends are returned to the wall or turned down so they cannot catch a sleeve.
Brackets need something solid behind them. A brick or block wall takes a plugged or resin fixing; a stud partition needs timber or steel backing fixed between the studs before it is boarded, and plasterboard alone will not do. This is the common reason a handrail fails to fit: the wall is built and lined before the rail is thought of. Tell us the wall construction and, for a stud wall, where the backing goes. We show the bracket positions on the elevation so the backing can be set out.
The height has two parts. On the flight the top is 900 to 1000 mm above the pitch line, and on a landing in a non-domestic building it is 900 to 1100 mm. Where the rail passes from flight to landing the drawing gives the height at each end of the change. In a non-domestic building the rail is continuous along flights and landings, and Approved Document K 1.36 adds that a second, lower rail goes at 600 mm over the pitch line where there is full-height structural guarding.
A wall rail is the simplest handrail to make and the lowest in price. The cost is in length, the number of bends and returns, and what each bracket is fixed to. In extreme cold or heat, the same paragraph asks for a surface that does not become excessively cold or hot to touch, and says that metals with relatively low conductivity may be suitable. External rails get that treatment more than internal ones.
More views
Renders and sheets from our sample projects: made-up jobs, modelled and drawn the way a real one is.

Is it right for you?
Good for
- Stairs inside houses and flats
- External steps beside a wall
Not for
- A stair with an open side and a drop: it needs guarding as well
- A wall that cannot take fixings, such as unbacked plasterboard
What the drawings show
- An elevation of the rail over every flight and landing, with the height above the pitch line dimensioned at the start and end
- Bracket positions along the rail with the spacing between them
- The rail ends: returned to the wall or turned down, with the 300 mm extension where it applies
- A section through the rail and bracket showing the 50 to 75 mm clear to the wall
- The wall construction and fixing type at each bracket, so backing can be set out
Questions
How high should a stair handrail be?
Approved Document K 1.34 says the top of the handrail is 900 to 1000 mm from the pitch line or floor. In buildings other than dwellings, the height on landings may be 900 to 1100 mm. In a house, Approved Document M volume 1 uses 850 to 1000 mm for the entrance steps, so we keep to the overlap of 900 to 1000.
How far should a handrail be from the wall?
50 to 75 mm, from Diagram 1.13 of Approved Document K. A handrail on cranked supports should also have at least 50 mm clear under the rail so a hand can wrap round it. We draw the bracket projection to give that gap.
What size and shape should the handrail be?
A circular rail of 32 to 50 mm diameter, or a non-circular one 50 mm wide and 39 mm deep with rounded edges and a radius of at least 15 mm. That is Diagram 1.13 of Approved Document K. A 42.4 or 48.3 mm tube fits.
Do I need a handrail on both sides of the stairs?
Yes if the stair is 1000 mm or wider (Approved Document K 1.34c). In buildings other than dwellings and in the common stairs of flats there must be a continuous rail on each side of the flights and landings. On a narrow stair, one side is the minimum.
Can I fix a handrail to a stud wall?
Only into solid backing fixed between the studs before the board goes on. Plasterboard on its own cannot hold a bracket. We show the bracket positions on the drawing so the backing can be built in when the wall is.