Basket07399 358543

Guides/How to measure for a balustrade or stair

How to measure for a balustrade or stair

You need a tape of at least 5 m, a level, a piece of string with a weight on it, a pencil and about 15 minutes. Below are the four sizes a balustrade or stair pack starts from, and the six photos that go with them.

How to measure for a balustrade or stair

The four sizes

As on the balustrades and stairs pack. Letters match the sketch.

  1. ALength of each run, or the stair’s width
  2. BHeight of the floor or landing above the ground below
  3. CFor a stair: floor to floor, and the space it lands in
  4. DWhat it fixes into, and how thick that is
ABCD

Length of each run: size A

Sketch the job first, with a number on every run. Then measure one run at a time, along the edge it will stand on, from the corner or wall at one end to the corner or wall at the other. Write each length on the sketch with an arrow showing where the tape started. For a stair, measure the width instead: clear between the walls or strings, at the narrowest point.

Corners are where people go wrong. Do not assume 90 degrees. Measure 1000 mm out along each leg from the corner, then measure the diagonal between those two marks. A square corner reads 1414 mm. If yours reads something else, send the reading and we draw the true angle.

Say whether the posts will stand on top of the edge or on its face. That changes where the run begins and ends, because a face-fixed post sits outside the slab line.

Balustrade and stair: measure checklist
MeasureFrom / toWhy we need it
A: length of each runCorner or wall to corner or wall, along the edge, one run at a timeSets the length of each rail and the post spacing
A: stair widthClear between walls or strings, at the narrowest pointSets the width of the stair and its handrails
B: the dropWalking surface down to the ground belowDecides the guarding and the height to draw
C: floor to floorFinished floor at the bottom to finished floor at the topSets the rise and the number of steps
C: the spaceLength, width and the lowest point overheadThe stair has to fit and keep its headroom
D: what it fixes intoThickness of the edge or upstand, material and finishes on topSets where the posts sit and what they fix to
Corner angle1000 mm out along each leg, then the diagonalShows whether a corner is square

Swipe the table sideways to see every column.

The height of the drop: size B

Measure from the walking surface of the floor or landing down to the ground below. Hang the weighted string over the edge and measure the string, or use a long tape held against the wall. Do not lean over the edge to read it. The drop decides whether guarding is needed on a stair or landing. In a dwelling, Approved Document K asks for it when the drop is more than 600 mm.

It also tells us the height to draw. In a house, guarding on a stair or landing is 900 mm, but an external balcony and the edge of a roof are 1100 mm. One house can need both, so say which parts of the job are outside. In flats and other buildings the figures differ, so tell us what the building is.

For a stair: floor to floor and the space: size C

Measure the finished floor at the bottom to the finished floor at the top, in one go if you can. Measure the space it lands in too: the length from the top edge back to the bottom, the width between walls, and the lowest thing overhead. Approved Document K asks for at least 2 m of headroom over the flight and landings.

If a stair already stands there, count the risers, then measure one rise (step to step, vertically) and one going (nosing to nosing, horizontally). The number of risers times the rise should match the floor to floor height. If it does not, the steps are uneven, and we want to know. We check rise, going and twice the rise plus the going on every stair in the pack.

What it fixes into: size D

Tell us what the balustrade or stair fixes to and how thick it is. For a slab edge, measure the thickness at an unfinished edge, a threshold or a hatch. For an upstand or a wall, measure the width across the top. Add the build-up on top: screed, tile, decking or membrane. Write the material down: concrete, brick, block, timber, steel or stone.

We need this because a post must sit a safe distance from an edge, and the fixing must go into something that can hold it. A fixing close to a slab edge or into thin concrete will not hold the load whatever the drawing says. Do not drill to find out. A photo of a cut edge is enough. Your fabricator or engineer confirms the fixing.

The six photos

The whole run or stair from a few steps back shows how the parts relate. Each end of the run, close up, shows where the rail stops, the wall or door it meets and the floor finish. What it fixes to, the edge, floor or wall, close up, is the most useful photo of all.

Any corners or steps, close up, because posts and rails change there. The stair from the side, if there is one, so we can read the rake and the landing. Last, anything in the way: doors that swing, drains, cables, light fittings. Keep the phone upright and put a tape or a 1 m stick in the shot for scale.

Levels and falls

A terrace or landing is often laid to a fall. Rest a level on a straight piece of timber on the floor at each end of a run, and measure the gap under the timber at its low end. Send both readings. Posts stand plumb whatever the floor does, so we need to know how far the floor drops along the run.

The same applies where a run steps up or down. Note the height of each step and where it sits along the run.

What we work out, and what happens next

We work out post spacing, infill, rail heights, the 100 mm gap and the fixing set-out. You do not need to measure those. Send the numbers raw. The pack arrives within 3 working days of a complete upload, and it tells the fabricator to check on site before making.

Questions

How do I measure for a balustrade?

Sketch the job and number each run. Measure each run along its edge, corner to corner, one at a time. Then measure the drop to the ground, and the thickness and material of what it fixes to. Add the six photos we ask for, with a tape in the shot for scale.

How high does a balustrade have to be?

In a house, 900 mm on a stair or landing and 1100 mm on an external balcony or the edge of a roof, from Diagram 3.1 of Approved Document K. Flats and other buildings differ. We check every run against its own figure.

How do I measure for a staircase?

Measure the finished floor at the bottom to the finished floor at the top, then the space it lands in: length, width and the lowest point overhead. If a stair already stands there, count the risers and measure one rise and one going.

Do I measure to the inside or the outside of the slab edge?

Along the face of the edge the posts will stand on or fix to. If the posts fix to the side of the slab, tell us, because they sit outside the slab line and the run starts and ends differently.

What if my corner is not square?

Measure 1000 mm out along each leg from the corner, then the diagonal between the two marks. A square corner reads 1414 mm. Send whatever you get and the sizes of both legs, and we draw the true angle, so the rails are cut to fit instead of forced on site.

Sources

Read on the published page. These guides are for England unless they say otherwise, and explain the documents: your council, building control body and engineer decide your job.

  1. Approved Document K: Protection from falling, collision and impact, 2013 edition (England), para 1.41, p.17“when there is a drop of more than 600mm”
  2. Approved Document K: Protection from falling, collision and impact, 2013 edition (England), para 1.11 and Diagram 1.3, p.7“provide the minimum headroom shown in Diagram 1.3”
  3. Approved Document K: Protection from falling, collision and impact, 2013 edition (England), Diagram 3.1, p.24“External balconies, including Juliette balconies and edges of roof”
  4. JPA Design: Balustrades and stairs design pack, What we need from you“Length of each run, or the stair's width”