Basket07399 358543

Homes and gardens/Stairs/External steel stair

External steel stair

A galvanised steel stair outside, to a first-floor flat, a garden, a deck or a podium, with its landing and guarding.

External steel stair

3D modelFrom sample project AQ15, rendered from the model.

What it is

Plate stringers carry chequer plate or grating treads between them, galvanised so they last outside, with the guarding up the flights and round the landings.

The stair is set out from the ground and the level it reaches, its rise and going checked, its foot fixed to a base and its head to the building or a landing frame.

Sizes and options

As we draw it. Every size is set to your job.

StringersPlate or channel
TreadsChequer plate or grating
Rise and goingChecked to Approved Document K
FinishGalvanised

Worth knowing

In flats, the stair's risers cannot be open.

A stair in the common areas of a building containing flats must have risers which are not open, and nosings in a contrasting material. In a house the rule is looser: open risers are allowed if the treads overlap by 16 mm and a 100 mm sphere cannot pass through them.

Source: Approved Document K, 2013 edition, paragraphs 1.9 and 1.10

The detail

How it is made, fitted and priced, and what to tell us.

Which category the stair is decides every dimension. Approved Document K gives three: a private stair serving one dwelling (rise 150 to 220, going 220 to 300, pitch no more than 42 degrees), a utility stair for escape or maintenance (rise 150 to 190, going 250 to 400), and a general access stair (rise 150 to 170, going 250 to 400). A stair that is a flat's only way out is not the same as a stair to a garden, and a stair that is both an escape and a route into a building has to meet the stricter of the two. Tell us which it is before anything else.

Escape is the second thing to settle. An external stair may serve a floor not more than 6 m above ground, so on taller blocks it is a podium or roof-terrace stair, not the main escape. The wall beside it is part of the fire design: Approved Document B asks for fire-resisting construction for a distance either side and above, with fixed shut glazing, so put the stair against a blank wall, not a bedroom window. The architect and fire engineer settle that; we draw it.

Treads are where the drawings and the regulations disagree most. Open-mesh grating and chequer plate are stock items, but in the common parts of a block of flats Approved Document K says risers must not be open. In a house, open risers are allowed if the treads overlap by 16 mm and a 100 mm sphere cannot pass. So a closed chequer-plate riser is usually the safer drawing, and grating is for utility or maintenance stairs.

The foot and the head are the fixing work. The foot goes on a base plate on a slab or pad, anchored with resin anchors, and the head bolts to the building or to a landing frame. Galvanised hollow parts need vent holes so the zinc can get in and drain, and those are on the drawing too. Send us the levels at the top and bottom, the structure at the head, the plan space and who will use the stair.

Is it right for you?

Good for

  • Flats over shops
  • Gardens on a slope
  • Decks and podiums

Not for

  • The only escape from the upper floors of a tall block: an external stair serves a floor no more than 6 m up

What the drawings show

  • A side elevation from ground to head, with the number of risers, the rise and the going written on it
  • Plan with the landing sizes and the clear width between the handrails
  • The foot and head fixings in section, with the anchor type and the plate size
  • The headroom line over the pitch, checked at 2 m
  • A parts list by mark, with the galvanising vent holes shown

Questions

Guide: Balustrade heights in the UKGuide: Stair rules in England: rise, going, headroomGuide: How to measure for a balustrade or stair

What are the rules for rise and going on an external stair?

It depends on the category in Approved Document K. A private stair has a rise of 150 to 220 mm and a going of 220 to 300 mm, with a maximum pitch of 42 degrees. Utility and general access stairs are tighter. Your building control officer confirms the category.

Can an external steel stair be a fire escape?

Yes, for a floor not more than 6 m above ground in a block of flats, and with fire-resisting construction in the wall beside it. On taller buildings it cannot serve the upper floors. The fire engineer decides the route.

Is grating allowed on an external stair?

In utility or maintenance stairs, usually. In the common parts of flats, Approved Document K says to use risers which are not open, so open grating alone does not do. Grating and plate can be combined, and in a house open risers are allowed if the treads overlap by 16 mm and a 100 mm sphere cannot pass.

How much headroom does an external stair need?

At least 2 m clear, measured vertically above the pitch line, and escape routes need 2 m clear except in doorways. We check this on the model against anything the stair passes under, such as a balcony soffit or a canopy, before the drawing is issued.

Does it need galvanising?

Outside, yes, if you want it to last. Hot-dip galvanising is the usual finish, and hollow sections need vent holes so the zinc can get in and drain. A coat of paint over the galvanising can be added where you want a colour. We note the finish on every sheet.

Your external steel stair, drawn from a real 3D model.

Balustrade and stair design pack: from £395

Back in 5 working days or your money back. Or call 07399 358543 to ask first.