Aluminium coping drawings

Folded aluminium copings over parapets and gables, every length and fitting marked, on board and membrane, with the joints over their straps.

Aluminium coping drawings

3D modelRendered from the model we draw from.

What it is

A coping falls to the roof side, laps over both faces with a drip, and joins over a strap with a gap for the metal to move. Corners and apexes are fittings of their own, mitred and welded.

Every length is drawn flat with its folds and holes, with a DXF for the folder.

Sizes and options

As we draw it. Every size is set to your job.

MaterialAluminium, polyester powder coated
JointsOver butt straps, with expansion gaps
UnderBoard and membrane

Worth knowing

LABC Warranty will not accept a coping with no fall.

LABC Warranty's parapet guide asks for a coping to shed water: at least 2 degrees from horizontal on its top surface, with 40 mm overhang each side and a throating or drip.

Source: LABC Warranty, Guide to creating weatherproof parapet walls

The detail

How it is made, fitted and priced, and what to tell us.

Copings are folded from 1050A H14 sheet on a press brake. The usual folded length is 3000 mm, which is what most suppliers' brakes and stock sheet suit, and the gauge follows the width: 2 mm up to about 450 mm wide, 3 mm over that. A wide coping on thin sheet oil-cans, so the width of your parapet decides the gauge before anything else does.

Aluminium moves. Over a 3 m length a light coping grows about 3.2 mm and a dark one about 3.8 mm, so every joint is drawn with a gap of that order, bridged by a butt strap at least 150 mm long under the joint. Each length gets one fixed screw, at mid-length, and every other hole is oversize so the metal can slide: at 1000 mm from the fixed point a 5.5 mm screw needs an 8 mm hole. The commonest site fault is every screw driven tight and the gaps filled with sealant, which buckles the coping and splits the joints. Our length sheets mark the fixed hole, the floating holes and the gap at each end.

The fall and the overhang are drawn from the wall, not from the coping. The wall's thickness, any render build-out and the cavity tray height all go on the section, so the overhang past each face and the drip are dimensioned from what is really there. Straps are screwed at no more than 1500 mm centres, set in from the wall face so the screws do not show.

Price follows the number of different parts, not the length. A plain run of one width is cheap; every corner, apex, end cap, step and change of width is a fitting of its own, mitred and welded, and a stepped parapet turns into dozens of unique pieces. Dark colours move about half as much again as light ones, which changes the gaps. Powder coat is the finish, and its warranty sets the life of the job more than the metal does.

Send us the parapet in plan with its thickness, any steps or corners, the roof build-up and the colour you want. A photograph of each corner saves a lot of back and forth.

More views

Renders and sheets from our sample projects: made-up jobs, modelled and drawn the way a real one is.

Copings - view 1, rendered from the 3D model
3D renderA real 3D model
Copings - view 2, rendered from the 3D model
3D renderA real 3D model

Is it right for you?

Good for

  • Parapets and gables

Not for

  • Stone, precast or clay copings: we draw folded aluminium only
  • Deciding the parapet's wall build-up: your architect and engineer do

What the drawings show

  • A run plan with every straight length, corner and apex fitting marked
  • The strap positions, the expansion gap at each joint and the fixed hole on every length
  • A flat pattern per length: blank, folds up and down, holes, with a DXF for the folder
  • A section through the coping, wall top, board and membrane, with the fall, overhang and drip dimensioned
  • A schedule of lengths, fittings and fixings

Questions

What fall does a parapet coping need?

A coping must shed water. LABC Warranty asks for a minimum fall of 2 degrees from horizontal on the top surface, and its guide does not accept a coping with no fall. It also asks for an overhang of at least 40 mm each side of the wall below and a throating or drip. Our drawings show all three on the section, taken from your wall thickness.

How long can one length of aluminium coping be?

Three metres is the usual length, because that is what most press brakes and stock sheets suit. Some workshops fold up to 6 m, but the industry guide limits that to light colours, because dark ones move more. Longer lengths also need a bigger gap at each end, so we draw three metres unless a run is short.

Why is there a gap between coping lengths?

Aluminium expands and contracts with temperature. A 3 m length moves a few millimetres, so a gap of about 3 to 4 mm is left at each joint and covered by a strap underneath. Fill it with hard sealant or butt the ends tight and the coping buckles or the joint opens.

What thickness is aluminium coping?

We draw 2 mm sheet for copings up to about 450 mm wide and 3 mm above that, in 1050A H14 aluminium, powder coated. Wider copings need the thicker sheet to stay flat between the folds. Narrow copings can use thinner sheet on other systems, but we keep to this rule so every part on a run behaves the same way.

What goes under a coping?

A board and a membrane sit between the wall top and the metal, and the straps are fixed through them into the wall. The drawing shows the build-up layer by layer so the roofer and the fixer both know what they are fixing through.

Send the drawings.

Send the drawings and get a fixed price back within 4 working hours (Mon-Fri, 8 am-6 pm).

Not ready to send drawings? Ask for the full sample pack for your type of work, or a call back, with the form.

Big files: paste a WeTransfer, Dropbox or Google Drive link, or send them when we reply.

Thanks, that’s with us.

We use your details only to answer you: privacy, terms.