Folded aluminium rainscreen cassettes on helping-hand brackets and rails, built on the edges they were tested with, round windows and corners.

Rainscreen cassette drawings

3D modelRendered from the model we draw from.

What it is

A cassette is a tray folded on four sides, hung on rails with its joints open behind a labyrinth. We build every panel on the edges of a tested system and check its size, stiffeners and wind against that test.

Openings and corners set the joints, and every panel is drawn flat with its DXF.

Sizes and options

As we draw it. Every size is set to your job.

PanelsPortrait 1200 x 1500 typical
FixingRails on helping-hand brackets
ChecksSize, stiffeners and wind against the tested line

Worth knowing

Tall residential walls must be A2-s1, d0 or A1.

Regulation 7(2) says materials that become part of an external wall of a relevant building must be Euroclass A2-s1, d0 or A1. Approved Document B reads that as buildings with a storey at least 18 m up. That includes the rails and fixings behind a cassette.

Source: The Building Regulations 2010, regulation 7(2) (England); Approved Document B vol 1, para 10.14

The detail

How it is made, fitted and priced, and what to tell us.

A cassette panel is a tray, 2 or 3 mm aluminium, folded on four sides with its corners welded or riveted and hung on rails. The tested construction we follow is 50 mm deep, with stiffeners across the back of larger panels. The size limit is set by the test, not by what the brake can fold: one tested 3 mm line goes to 1500 x 3850 mm with six stiffeners at 610 mm, while a 2 mm panel of 600 x 3850 mm goes without stiffeners but only to 2000 Pa.

That is why we check every panel against a tested line. The wind pressure is read from the job, the panel size and stiffener spacing from the test table, and anything outside is flagged before it is made. Portrait panels of 1200 x 1500 mm are the default because a portrait panel is fixed on its two long sides alone, as tested. Cut a panel down round a window and it may become landscape, which the test treats differently, and the checks say so.

The edges do the weather-proofing. Side returns are about 50 mm with a short outward leg, and one panel overlaps its neighbour so the vertical joint is closed. The top edge turns up to form a labyrinth behind the panel above, and the bottom edge turns in. Screws go through the overlapped returns at no more than 500 mm centres. These are what a panel loses when it is made to suit, and then the water finds the gap.

Openings set the joints. We put a joint on each window surround and cill line and turn face ends in at corners and openings. Rails stop either side of an opening so each panel keeps the support it had in the test.

Cost goes with the number of unique panels, the stiffeners and the finish. Tell us the building height and location, the facade drawing, the rail system if there is one, and the fire classification needed.

More views

Renders and sheets from our sample projects: made-up jobs, modelled and drawn the way a real one is.

Rainscreen cassettes - view 1, rendered from the 3D model
3D renderA real 3D model

Is it right for you?

Good for

  • Facades and soffits

Not for

  • Composite panel systems: a different type of cladding
  • Designing the wind load: the facade engineer does

What the drawings show

  • A facade elevation with every panel marked by size and joint line
  • Sections through the joints, head, cill and corner: returns, labyrinth and rails dimensioned
  • A flat pattern per panel with folds, rivet holes and stiffener positions, and a DXF
  • Rail and bracket positions, including at openings and corners
  • A schedule of panels with the wind check against the tested line

Questions

How big can an aluminium cassette panel be?

It depends on the tested system. One tested line in 3 mm aluminium goes to 1500 x 3850 mm with six stiffeners; a 2 mm panel is far smaller. We check each panel against a test result and flag anything outside it before manufacture.

What is the difference between a cassette and a flat composite panel?

A cassette is a folded tray in solid aluminium sheet, stiffened and hung from rails. A composite panel is a bonded sandwich with a core. Regulation 7(1A) bans relevant metal composite materials in external walls at any height, which is one reason solid sheet is chosen.

Do rainscreen panels need fire evidence?

On relevant residential buildings with a storey at least 18 m up, every material in the external wall must be Euroclass A2-s1, d0 or A1. The sheet, rails, fixings and finish all need evidence. We state the class assumed on the drawing and ask for the test or assessment reference.

What fixes a cassette to its rails?

Screws through the folded returns into the rails, at no more than 500 mm centres on the tested system. One fixed point and slots elsewhere let each panel move. The joint relies on the overlap and the labyrinth rather than sealant, so the screw positions are marked on each panel's flat pattern instead of being left to site.

Can cassettes go round a window?

Yes. Joints are set on the window surround and cill lines, rails stop either side, and edges turn in at the opening. The panel sizes round the window are then checked again, because cut-down panels can fall outside the tested line.

Send the drawings.

Send the drawings and get a fixed price back within 4 working hours (Mon-Fri, 8 am-6 pm).

Not ready to send drawings? Ask for the full sample pack for your type of work, or a call back, with the form.

Big files: paste a WeTransfer, Dropbox or Google Drive link, or send them when we reply.

Thanks, that’s with us.

We use your details only to answer you: privacy, terms.