Welded mesh panels clamped to steel posts, the posts in concrete footings, stepped down slopes so the gap under the mesh stays small.

Mesh security fencing

3D modelFrom sample project AL05, rendered from the model.

What it is

Mesh fencing goes up panel by panel: posts at the panel centres, each panel clamped to the attack face. On a slope the panels step, never rake, so the gap at the bottom stays within the limit.

Gates and pedestrian gates are drawn into the same runs, with their own posts and foundations.

Sizes and options

As we draw it. Every size is set to your job.

Mesh358 or 868 welded mesh panels
Panels2515 mm on 2440 mm centres
PostsRHS 80 x 60, clamp bars
Footings450 x 450 x 900 mm
Steps165 mm maximum on a slope

Worth knowing

Over 2 m needs planning permission.

A new fence, gate or wall beside a highway used by vehicles is only permitted up to 1 m; anywhere else, up to 2 m. Our standard 358 mesh is 2.44 m high, so a full-height security line usually needs the council's permission, however it is made.

Source: The Town and Country Planning (General Permitted Development) (England) Order 2015, Schedule 2, Part 2, Class A, A.1(b)

The detail

How it is made, fitted and priced, and what to tell us.

Mesh fencing is bought by panel and put up by the post, so the drawing is mostly arithmetic. Our 358 system uses panels 2515 wide on posts at 2440 centres, RHS 80 x 60 x 3, each panel clamped to the post with a flat bar 30 x 6 and M8 coach bolts at 304.8 pitch. Every post sits in a 450 x 450 x 900 footing, with about 700 of it buried. The security nuts and bolts face the public side, and the mesh goes on the attack face, the side an intruder would stand on, so he cannot reach the clamps to undo them.

Ground is where it goes wrong. Mesh panels are rigid and cannot follow a slope, so they step. The mesh is built on a 12.7 vertical grid, which means a step is always a whole number of those, and the largest step our data allows is 165 on a slope up to about 1 in 5. The gap under the mesh may not exceed 50, with a bury of up to 150 on soft ground. Each panel, every post length and every footing is set out on the long section, so the fabricator and the groundworker can both see the step at every post. Direction changes above about 45 degrees need a corner post, drawn separately, with the panels stopped short of it on cleats.

The choice between mesh and palisade changes price and look. Palisade (our W pale, triple point) is bays of 2750 with two angle rails EA 50 x 50 x 6, 17 pales to a bay, on IPE 100 posts, and it rakes with the ground more easily than mesh. It looks heavier and keeps people away, but you cannot see through it as well. Mesh is lighter, quicker to put up and lets cameras and people see through it. Both can be certified systems to LPS 1175 if the job needs a rated fence; a bespoke build from separate parts is not certified.

Gates are part of the run. A fence with a vehicle gate and a pedestrian gate beside it needs jamb posts, foundations and the automation drawn in the same set. Tell us the line of the boundary, the levels along it, the height you need, what the fence protects and whether it needs a rating. We draw the posts, the steps, the footings and the gate openings; the rating, if you need one, comes from the maker's tested system.

More views

Renders and sheets from our sample projects: made-up jobs, modelled and drawn the way a real one is.

Mesh security fencing - view 1, rendered from the 3D model
3D renderSample project AL05
AL05-FG-20 358 mesh fence, type GA and section
AL05-FG-20358 mesh fence, type GA and section

Is it right for you?

Good for

  • Depots, yards and schools
  • Sites that need to be seen through

Not for

  • Boundaries needing a certified rating if you only have the steel sizes, since a rating comes with the maker's tested system
  • Sites where the fence must be pushed over slopes steeper than about 1 in 5

What the drawings show

  • Plan of the fence line with every post numbered and the panel centres dimensioned
  • Long section along the fence showing ground levels, every panel step and the gap under the mesh
  • Post, clamp bar and footing detail at 1:10, with the bolts on the attack face
  • Corner posts, direction changes and the panels stopped short on cleats
  • Gate openings with jamb posts and foundations drawn into the same run
  • A post and panel schedule for the order

Questions

Guide: Driveway gate height, opening and automationGuide: How to measure for driveway gatesGuide: How to measure for railingsGuide: How to measure for yard gates and fencingGuide: How to make a steel garden gate that hangs true

How high can a security fence be without planning permission?

In England, a new fence or gate is permitted development up to 2 m, or 1 m next to a road used by vehicles. Our 358 mesh system is 2.44 m high, so it normally needs permission unless it is on a site where permission already covers it. Check with your council.

What is 358 mesh?

A welded mesh with 76.2 mm horizontal and 12.7 mm vertical openings and 4 mm wire. The openings are too small for fingers or toe holds and too small for bolt croppers to reach, which is why it is used on secure sites. In our library it is the base for LPS 1175 SR1 certified systems.

How do you fence a sloping site with mesh panels?

By stepping the panels, not raking them. Each panel stays level and the next one starts higher or lower on its post. Our data allows a step of up to 165 on a slope up to about 1 in 5, while keeping the gap under the mesh to 50 at most. The long section shows every step.

What is the difference between mesh and palisade?

Mesh is lighter and you can see through it. Palisade is pales bolted to rails on heavy posts: harder to climb and bulkier to look at, and its rails follow a slope more easily. Palisade bays here are 2750 wide with two angle rails and 17 pales; mesh panels are 2515 on 2440 centres.

Does the fence need to be certified?

Only if your insurer, client or site rules say so. A certified system to LPS 1175 is bought as the maker's tested kit and fitted to their instructions. A fence built to the same sizes from separate parts is not certified. Tell us at the start, because it limits which components the drawings can use.

Your mesh security fencing, drawn from a real 3D model.

Yard gate and fencing design pack: from £495