Basket07399 358543

Homes and gardens/Balustrades/Plant guarding

Roof and plant guarding

Galvanised tube and fittings round roof plant and plant decks: base fixed, or counterweighted where the roof must not be drilled.

Roof and plant guarding

3D modelRendered from the model we draw from.

What it is

Tube-and-fitting guarding goes up without welding: uprights on base flanges, a top rail at 1100 mm and a knee rail, with the fittings named at every node. Where the roof membrane cannot be pierced, counterweighted posts stand on it.

Bays are set from the maker’s load chart and toe boards added where things could be kicked off the edge.

Sizes and options

As we draw it. Every size is set to your job.

The model with its sizes
3D with measuresThe sizes are the model’s own
Tube48.3 x 4 galvanised
Top rail1100 mm, knee rail 550 mm
FixingBase flanges with two M12 anchors, or counterweighted
Toe boardsWhere needed

Worth knowing

How often you go up decides whether guarding is permanent.

Approved Document K says that where maintenance access will be needed frequently, for example at least once a month, the guarding follows the same provisions as elsewhere. Where access is needed less often, temporary guarding or warning notices may be appropriate under the Work at Height Regulations 2005.

Source: Approved Document K (2013 edition), paragraph 3.4

The detail

How it is made, fitted and priced, and what to tell us.

Tube and fitting guarding is bolted together, not welded. Malleable iron fittings are clamped by set screws onto galvanised tube, so it goes up on a roof without hot work. We draw the top rail at 1100 mm and a knee rail 550 mm below it, with every fitting named at its node, so the order is a list of fitting types and cut lengths, not a drawing to be interpreted on a roof.

Bay length is set by the maker's load chart. For 48.3 x 3.2 medium tube, uprights 1100 mm high on a Type 62 base flange, the chart gives bays of about 2315 mm for a 0.36 kN/m load, 1126 mm for 0.74 kN/m and 555 mm for 1.5 kN/m, before any safety factors. The jump between those figures is why the load class has to be known before the posts are counted, and why your engineer's figure is the starting point.

Where the roof must not be drilled, counterweighted guarding stands on the membrane. The FH Brundle Defender system has 1100 mm posts with an integral toe plate and PVC counterweights, no fixings through the roof, posts at up to 2000 mm centres and flat roofs to a maximum 3 degrees. KeeGuard's operating manual says it is wind-calculated per site to BS 13700:2021, that nobody should be attached to it, and that it needs annual inspection. It is edge protection, not an anchor point.

Toe boards stop things being kicked off. FH Brundle's FAQ says one is needed where the roof edge has no solid upstand or parapet of at least 100 mm. Tell us the roof build-up and fall, whether the membrane can be pierced and by whom it will be sealed, and what the weather is like on site: on an exposed roof, counterweights are wind-calculated and can become large. Base-fixed guarding costs less than counterweighted, which needs more steel and a calculation, but it costs a membrane repair at every post.

More views

Renders and sheets from our sample projects: made-up jobs, modelled and drawn the way a real one is.

Plant guarding - view 1, rendered from the 3D model
3D renderA real 3D model
Plant guarding - view 2, rendered from the 3D model
3D renderA real 3D model

Is it right for you?

Good for

  • Flat roofs and plant decks
  • Roof access routes
  • Where the membrane must not be drilled

Not for

  • Homes and public areas: see the bar types

What the drawings show

  • A roof plan with the guarding line, the corners and the gates or openings dimensioned from the roof edge
  • A fitting list per node with the tube cut lengths
  • The bay lengths set from the load chart, with the base fixing or counterweight marked on each post
  • A section through the base flange or counterweight on the roof build-up
  • Toe board lengths and the gaps measured to the toe board where one is used

Questions

Guide: Balustrade heights in the UKGuide: How to measure for a balustrade or stair

How high must roof edge guarding be?

Approved Document K Diagram 3.1 gives 1100 mm for the edges of roofs on houses, flats and non-domestic buildings. Industrial guarding to BS EN ISO 14122-3 also uses a 1100 mm top rail, as quoted by Kee and GT Engineering. We draw 1100 mm with a knee rail below.

Do I need a toe board on a roof edge guardrail?

Often yes. FH Brundle's guidance says a toe board is needed where the roof edge has no solid upstand or parapet of at least 100 mm. We draw the toe board with its fixings where the edge needs one, and show the gap measured to it.

Can guardrail be fixed to a flat roof without drilling?

Yes, with counterweighted guarding, which stands on the membrane. It is wind-calculated for the site, and is limited to flat roofs of up to about 3 degrees in the FH Brundle Defender system. Drilled guarding needs the membrane sealed at each post.

How far apart can Kee Klamp posts be?

It depends on the load class. For 48.3 x 3.2 medium tube on a Type 62 base, the maker's chart gives about 2315 mm for 0.36 kN/m, 1126 mm for 0.74 kN/m and 555 mm for 1.5 kN/m, before safety factors. We draw the bay lengths from that chart.

Does permanent guarding have to be fitted for a roof only used for maintenance?

Not always. Approved Document K 3.4 says that where access is needed less than once a month, temporary guarding or warning notices may be appropriate, with the Work at Height Regulations 2005 setting the measures. Where it is needed more often, the guarding follows the same heights as any other edge.

Send the drawings.

Send the drawings and get a fixed price back within 4 working hours (Mon-Fri, 8 am-6 pm).

Not ready to send drawings? Ask for the full sample pack for your type of work, or a call back, with the form.

Big files: paste a WeTransfer, Dropbox or Google Drive link, or send them when we reply.

Thanks, that’s with us.

We use your details only to answer you: privacy, terms.