Basket07399 358543

Homes and gardens/Balustrades/Vertical bars

Vertical bar balustrade

Steel bars between posts at less than 100 mm clear, galvanised and powder coated: the type that takes the most knocks and needs the least looking after.

Vertical bar balustrade

3D modelRendered from the model we draw from.

What it is

Vertical bars cannot be climbed like rails can, and the gap between them is set so a 100 mm sphere cannot pass. The bars sit in panels between the posts, or in a frame welded up in the shop.

Round or square posts, round or square bars, and a handrail on top or the top rail as the handrail: the type takes the look of the building it goes on.

Sizes and options

As we draw it. Every size is set to your job.

The model with its sizes
3D with measuresThe sizes are the model’s own
PostsSHS 50 x 50 or CHS
BarsSQ 16 or RB 16 at no more than 95 mm clear
RailsFL 40 x 10 top and bottom
HandrailCHS 42.4 on saddles
FinishGalvanised and powder coated

Worth knowing

The gap is 100 mm, measured clear.

Where children under five may use the building, a 100 mm sphere must not pass through any opening in the guarding. With 16 mm bars we set them at no more than 95 mm clear, so the rule is met with room for the tolerance of making and fitting.

Source: Approved Document K, 2013 edition, paragraph 3.3

The detail

How it is made, fitted and priced, and what to tell us.

Bars at no more than 95 mm clear means a 16 mm bar every 111 mm or less, about nine bars to the metre of run. We set the gap equally across each panel, so a panel never ends with one wide gap beside a run of tight ones. The bars sit between top and bottom rails of FL 40 x 10 laid flat, or between SHS rails in a welded frame. The bottom rail stands 50 mm over the floor or the stair pitch line on a top fix, so no gap under it passes the sphere.

Fixing is the part that changes with the job. A top fix puts the base plate on the slab with the post centre about 100 mm in from the edge, a convention taken from the major rail makers' set-outs. A face fix uses a PL10 plate 200 x 100 with two M12 resin anchors, and a core fix sets the post in a hole drilled in the slab, 125 mm back from the edge. Each needs concrete around the anchors, so the slab thickness and the edge condition decide which is allowed.

Galvanising thin-walled tube is where the finish often falls short of what people expect. An SHS 50 x 50 x 3 falls in the 1.5 to 3 mm wall band of BS EN ISO 1461, with a minimum mean coating of 55 microns against 85 for steel over 6 mm. The Galvanizers Association says life is proportional to coating thickness, so thin tube has less of it. Hollow sections must be vented, and for a section of 50 mm the minimum vent hole in BCSA SN50 is 12 mm. Powder coating on top, a duplex system, is drawn with the note to tell the galvaniser.

This is the type that takes the most knocks and needs the least looking after: wash it, touch in chips on the coating, and look at the base plates and bolts once a year. Price depends on the number of posts and the bar count, since each bar is cut, placed and welded, and on whether the panels are made as a loose set or welded into a frame. Tell us the edge, the level of the finished surface and any stair rake, and we set out the rest.

More views

Renders and sheets from our sample projects: made-up jobs, modelled and drawn the way a real one is.

Vertical bars - view 1, rendered from the 3D model
3D renderSample project AQ15
Vertical bars - view 2, rendered from the 3D model
3D renderSample project AQ15
Vertical bars - view 3, rendered from the 3D model
3D renderA real 3D model

Is it right for you?

Good for

  • Balconies, stairs and landings
  • Public and shared areas
  • Anywhere it will be leaned on

Not for

  • Where the view through matters most: see glass

What the drawings show

  • Each panel's length and bar count, with the clear gap between bars worked out and dimensioned
  • Post positions chained from a datum on the edge, with the base plate or face plate shown
  • A 1:5 section through the fixing, the post, the bottom rail and the rail on top
  • The clear height from the floor or pitch line to the bottom rail, so the sphere check is shown
  • A parts list with the vent holes and the finish note on the sheet

Questions

Guide: Balustrade heights in the UKGuide: Stair rules in England: rise, going, headroomGuide: How to measure for a balustrade or stair

What is the maximum gap between balustrade bars?

Less than 100 mm, so a 100 mm sphere cannot pass. Approved Document K applies the 100 mm sphere to buildings that may be used by children under five, and we apply it everywhere. Our bars are set at no more than 95 mm clear to leave a few millimetres for making and fitting.

How high must a balcony balustrade be?

Approved Document K Diagram 3.1 gives 1100 mm for an external balcony on a house, including a Juliet balcony, and for edges of roofs. On flats and other buildings the guarding is 900 mm on stair flights and 1100 mm elsewhere. Guarding at an opening window is 800 mm.

How many bars do I need per metre?

With a 16 mm bar and a gap of 95 mm or less, the pitch is no more than 111 mm, which is about nine bars to the metre. We work the exact count from each panel length so the gaps come out equal.

Can I put the handrail on top of vertical bar guarding?

Yes. Approved Document K 1.34 allows the handrail to form the top of the guarding if the heights match. On a stair flight the handrail goes 900 to 1000 mm above the pitch line, which is why a handrail on saddles sits on the posts.

Does galvanised balustrade need painting?

Not to protect it. A coating of 55 to 85 microns on galvanised steel resists corrosion on its own. Powder coating over it is for colour and a longer life, and the galvaniser has to be told so the surface is prepared for it.

Your vertical bars, drawn from a real 3D model.

Balustrade and stair design pack: from £179

Back in 3 working days or your money back. Or call 07399 358543 to ask first.