Tools/Welds and bolts/Fillet weld calculator
Fillet weld calculator
The leg and throat of a fillet weld, its cross-section, the weld metal per metre (or per foot), and the wire or electrodes to buy for the length, by process.
The calculator needs JavaScript, which is switched off or still loading. Everything else on this page reads without it.
Next step
- Get it drawnFabrication drawings with every weld in full to ISO 2553, the throat or leg stated, and the general weld note on every sheet. A fixed price within four hours.Price the drawings
- Build from a planReady-made workshop plans, welding tables, carts and racks, with every weld marked and every bar nested to stock.See the workshop plans
Works in millimetres and kilograms or inches and pounds: switch inside the tool. ISO 2553 drawings, as used in the UK and Europe, mark a fillet's size with a or z; check which before you price.
Worth knowing
An a6 fillet is twice the weld of a z6.
ISO 2553 sizes a fillet weld two ways: a, the throat, the height of the largest isosceles triangle that fits in the weld, and z, the leg. On an equal-leg fillet the throat is 0.707 of the leg, so the same number means two different welds. z6 is a 6 mm leg with 18 mm² of section. a6 is a 6 mm throat: an 8.5 mm leg and 36 mm², twice the weld metal and twice the wire. TWI notes that UK drawings often give the leg while European ones usually give the throat, so the same steelwork can arrive marked either way. Read the letter in front of the number before the job is priced or welded.
Source: ISO 2553:2019, definitions 3.16, nominal throat thickness a, and 3.17, leg length z (iso.org); TWI Job Knowledge, 'Fillet welded joints: a review of the practicalities' (twi-global.com). Throat = leg x cos 45°, by geometry.
How it works
The arithmetic, the data it uses and where it stops.
Choose the units and say what the drawing gives: the leg, z, or the throat, a. Type the size, the length of weld and whether it is welded one side or both, then the process and how full the weld face is. The tool gives both the leg and the throat, the weld metal a metre or a foot, the total, and the wire or electrodes to buy.
An equal-leg fillet of leg z is a right triangle of z²/2 in section, with a throat of z x 0.707. A fillet given by its throat a therefore has a leg of a x 1.414 and a section of a². Real welds stand proud of that flat face, so Kobelco's consumption figures add the reinforcement as a share of the triangle: 15% in the flat position, 30% horizontal, 45% vertical up, and 20% in their simplified table. The tool's default is the 20%.
Weld metal is the section times the length times 7.85 g/cm³. The wire or electrodes to buy is that divided by the deposition efficiency, the share of the consumable that ends up in the joint. Kobelco gives 95% for solid MIG/MAG wire, 90% for flux-cored wire, 55% for covered (stick) electrodes and 100% for solid submerged-arc wire.
Checked against Kobelco's own Table 4.7: a 6 mm leg with 20% reinforcement takes 0.308 kg of covered electrodes or 0.179 kg of solid wire a metre of weld. The tool gives 0.308 and 0.178; Kobelco round their wire figure up to three places. The table under the result does the same sum for the common leg sizes with your process.
This is an estimate of consumables, not a weld design: the size a joint needs comes from its design and the drawing. Allow on top for tacks, run-on and run-off, and wire left on the spool.
Questions
What is the difference between a and z on a weld symbol?
a is the throat thickness and z the leg length (ISO 2553). On an equal-leg fillet z = a x 1.414, so an a5 weld has a 7.1 mm leg and a z5 weld a 3.5 mm throat.
How do I convert throat to leg?
Multiply the throat by 1.414, the square root of 2, for an equal-leg fillet: a4 is a 5.7 mm leg, a5 7.1, a6 8.5 and a8 11.3. Divide a leg by 1.414 for its throat.
How much weld metal is in a 6 mm fillet weld?
A 6 mm leg is 18 mm² of section: 0.14 kg of weld metal a metre with a flat face, 0.17 kg with Kobelco's typical 20% reinforcement. A 6 mm throat is twice that.
How much wire do I need for a fillet weld?
The weld metal divided by the deposition efficiency. With solid MIG/MAG wire at 95%, a 6 mm leg takes 0.18 kg a metre; with stick electrodes at 55%, 0.31 kg (Kobelco Table 4.7, with 20% reinforcement).
Why does a slightly bigger fillet take so much more wire?
The section goes with the square of the size: an 8 mm leg has 1.78 times the metal of a 6 mm one, and a 10 mm leg 2.78 times. Weld to the size on the drawing.
More free tools
Calculators for buying, cutting and fitting steel.
Steel weight calculator
UB, UC, PFC, angles, hot and cold hollow sections, bars and plate, from the BS EN tables. Build a list and get the total.
Hot-finished and cold-formed SHS do not weigh the same.USSteel weight per foot calculator
Every W, HP, S, C, MC, angle, HSS and pipe in the AISC Shapes Database, plus bar and plate, in pounds per foot.
An HSS weighs more than its listed area says.Metric and imperialCutting list optimiser
Nest cut lengths into 6 m, 7.5 m, 20 ft or 24 ft bars with the saw cut allowed for, searched for the fewest bars.
Longest-first can buy a bar you do not need.UK and USBaluster spacing calculator
Equal gaps between posts under the 100 mm sphere (UK) or the 4 in sphere (US), with every bar set out.
On a stair, the UK and US rules part company.Metric and imperialPlate weight calculator
Rectangles, discs and rings with holes, in steel, stainless or aluminium: the weight to lift and the plate it is cut from.
A disc is 78.5% of the plate it is cut from.Metric and imperialGate weight and hinge load calculator
The leaf weight from its frame and bars, the centre of gravity, and the pull on the top hinge.
The top hinge carries more than the gate weighs.Metric and imperialBend allowance calculator
The flat blank for a folded part from its legs, angles and thickness, with the radius the die will really give and every bend line set out.
On a press brake the die sets the radius, not the drawing.UK and USSheet metal gauge chart
Gauge to millimetres and back in the UK Standard Wire Gauge and the US steel, galvanized, stainless and aluminium tables, side by side.
16 gauge is five different thicknesses.UKGalvanising calculator
Vent and drain holes for sealed hollow sections, and the zinc a part picks up, to EN ISO 14713-2 and EN ISO 1461.
A sealed SHS 100 needs a 30 mm vent hole, not 10.UKBolt hole sizes
Normal, oversize and slotted holes for M12 to M30 bolts to EN 1090-2, with the minimum edge distances and spacings.
An M12 hole is 13 mm, not 14.USBolt hole size chart
Standard, oversized and slotted holes for 1/2 in to 1 1/2 in structural bolts, from RCSC Table 3.1, with the washers they call for.
The 1/16 in rule stops at 7/8 in.UKSteel paint calculator
Paint or powder for a list of UK sections: the area from the Blue Book tables, then litres or kilograms by coats and method.
A tonne of steel can be 2.2 m² of paint, or 68.UKStair calculator
Risers, going, pitch and 2R + G for a floor-to-floor height, the flights and landings, the stairwell opening and the handrails, checked against Approved Document K.
At a 220 mm rise, a private stair's going has 16 mm of room.UKSpiral and curved stair calculator
Treads a turn, the going on the line it is measured on, the narrow end and the headroom under the turn above, for spiral, helical and curved stairs.
Under 1 m wide, a tapered tread is measured on its centre line.UKRamp gradient calculator
Flights, landings and overall length for a ramp of any rise, checked against Approved Documents M and K, or the gentlest gradient that fits the space.
At 1:12 a ramp flight may run only 2 m.UKBalustrade height checker
The guarding height for the building and the place, whether guarding is needed at that drop, and the 100 mm sphere, from Approved Document K.
The 600 mm rule is for homes only.Metric and imperialPost hole concrete calculator
Concrete for fence and gate posts: the hole less the post, in litres and 20 kg bags of Postcrete or concrete mix, with the hole checked against the makers' guidance.
Postcrete is for gates under 1 m wide.Metric and imperialTap drill size chart
The drill for every metric coarse and fine thread from M1.6 to M42, for cutting and forming taps, with the thread depth it leaves.
A forming tap needs a bigger hole than a cutting tap.Metric and imperialmm to inches converter
Millimetres to inch fractions to 1/64, feet and inches, kilograms to pounds, and a chain of dimensions converted without the rounding creeping.
Round the running total, not each dimension.UKSteel cost calculator
Price a list of sections by the stock bars you will actually buy: nested section by section with the saw cut, at your price a kilogram, with the extras.
You pay for the bar, not the piece.USADA ramp slope calculator
Runs, landings and overall length for a ramp of any rise under the 2010 ADA Standards, or the gentlest slope that fits the space.
Under the ADA a ramp run is limited by its rise, not its length.On iLuvFreeTools, our sister site
- Metal weight calculatorAny metal by its dimensions: hex bar, tube, angle, with galvanising.
- Section propertiesEvery UK UB, UC and PFC with the depth the serial size does not give you.
- Wide flange beam sizesEvery W, HP, S, C and MC shape, and why the number is not the depth.
- Steel grade referenceS275, S355, A36 and A992 side by side.
- Staircase calculatorRise, going and pitch, including the combination the table quietly forbids.
- Timber quantity and cut listThe same saw-cut logic for timber boards.