Tools/Steel and plate weights/Steel weight calculator
Steel weight calculator
Every UK section from the Blue Book tables, with hot-finished and cold-formed hollow sections kept apart. Add each length to the list for the total weight, the paint area and the cost.
| Section | Length mm | Qty | Each kg | Total kg | Remove |
|---|
The calculator needs JavaScript, which is switched off or still loading. Everything else on this page reads without it.
Next step
- Get it drawnFabrication drawings for your frame: a sheet per mark, plate DXFs, NC1 files and a cut list nested to stock. A fixed price within four hours.Price the drawings
- Nest the lengthsTurn the list into stock bars with the saw cut allowed for, and see the offcuts before you order.Open the cutting list optimiser
Written for UK sections to the BS EN tables. Working to American shapes? Use the steel weight per foot calculator, which reads the AISC Shapes Database.
Worth knowing
Hot-finished and cold-formed SHS do not weigh the same.
An SHS 100x100x5 hot finished to BS EN 10210 is 14.7 kg/m. The cold-formed one to BS EN 10219, the same size on the order, is 14.4 kg/m. Across the tables the gap reaches 6.4%: SHS 180x180x12.5 is 64.4 kg/m hot finished and 60.5 kg/m cold formed. The difference is in the corners. The tables draw a hot-finished corner with an outside radius of 1.5 times the wall, a cold-formed one at 2 to 3 times the wall, so there is less steel in it. Round CHS have no corners, so the same size weighs the same either way. A weight list or an order that just says SHS is guessing which one it means.
Source: Steel for Life Blue Book, hot-finished and cold-formed SHS tables, with the corner radii the Blue Book quotes from BS EN 10210-2 and BS EN 10219-2 (hot finished, cold formed).
How it works
The arithmetic, the data it uses and where it stops.
Pick a section and a size, type a length in millimetres and how many, and add it to the list. Each row is the mass per metre from the published table, times the length, times the quantity. The list keeps a running total in kilograms and tonnes, the outside surface area for paint or galvanising where the table gives one, and the steel cost if you type a price per kilogram.
The rolled sections (UB, UC and PFC) are the BS EN 10365 sizes, the angles are BS EN 10056-1, and the hollow sections are two separate tables for each shape: hot finished to BS EN 10210 and cold formed to BS EN 10219. Pick a hollow section and the tool tells you what the other standard's tube of the same size weighs, so you can see the difference before it reaches an order.
Flats, rounds, squares and plate are not tabulated, because any size can be rolled or cut. They are worked from their area at 7,850 kg/m³, the density the Blue Book itself weighs every section at. A flat 50x10 comes out at 3.93 kg/m, a round bar 16 at 1.58 kg/m.
A size marked + is one the Blue Book lists as an additional size, outside the standard's own range. It is rolled, but not every stockist carries it, so check before you design around it.
The weights are the tables' nominal masses. Mill sections are rolled to tolerances, so a weighbridge ticket will not match to the kilogram; for a lift or a wagon, add the margin your own procedure asks for. The paint area is the outside surface only, which is what painters and galvanisers price on.
Questions
How do you work out the weight of a steel beam?
Multiply its mass per metre by its length. A UB 203x133x25 is 25.1 kg/m, so a 6 m length is 150.6 kg. The mass per metre comes from the section tables; the calculator looks it up for every UK size.
Does the last number in a UB size tell me its weight?
Nearly, not exactly. It is the nominal mass rounded to a whole kilogram: a UB 610x178x100 is 100.3 kg/m. The first number is not the depth either: a UB 203x133x25 is 203.2 mm deep and a 203x133x30 is 206.8 mm.
What density does the calculator use for steel?
7,850 kg/m³ for bars and plate, the figure the Blue Book uses for every section it tabulates. Rolled and hollow sections use the published mass per metre directly.
Why does my supplier's SHS weight differ from this?
Usually because one of you is reading the other standard. Hot-finished (BS EN 10210) and cold-formed (BS EN 10219) SHS of the same size differ by 1% to 6.4%, because their corners are drawn to different radii. Pick the standard that is on the order.
How do I weigh a flat bar?
Width times thickness in millimetres, times 7.85, divided by 1,000, gives kg per metre. FL 50x10 is 50 x 10 x 7.85 / 1,000 = 3.93 kg/m. Choose Flat in the calculator and type the two sizes.
Does the weight include galvanising?
No, it is bare steel. Galvanising adds weight in proportion to the surface area rather than the steel weight, which is why the calculator gives you the paint and galvanising area alongside.
More free tools
Calculators for buying, cutting and fitting steel.
Steel weight per foot calculator
Every W, HP, S, C, MC, angle, HSS and pipe in the AISC Shapes Database, plus bar and plate, in pounds per foot.
An HSS weighs more than its listed area says.Metric and imperialCutting list optimiser
Nest cut lengths into 6 m, 7.5 m, 20 ft or 24 ft bars with the saw cut allowed for, searched for the fewest bars.
Longest-first can buy a bar you do not need.UK and USBaluster spacing calculator
Equal gaps between posts under the 100 mm sphere (UK) or the 4 in sphere (US), with every bar set out.
On a stair, the UK and US rules part company.Metric and imperialPlate weight calculator
Rectangles, discs and rings with holes, in steel, stainless or aluminium: the weight to lift and the plate it is cut from.
A disc is 78.5% of the plate it is cut from.Metric and imperialGate weight and hinge load calculator
The leaf weight from its frame and bars, the centre of gravity, and the pull on the top hinge.
The top hinge carries more than the gate weighs.Metric and imperialBend allowance calculator
The flat blank for a folded part from its legs, angles and thickness, with the radius the die will really give and every bend line set out.
On a press brake the die sets the radius, not the drawing.UK and USSheet metal gauge chart
Gauge to millimetres and back in the UK Standard Wire Gauge and the US steel, galvanized, stainless and aluminium tables, side by side.
16 gauge is five different thicknesses.UKGalvanising calculator
Vent and drain holes for sealed hollow sections, and the zinc a part picks up, to EN ISO 14713-2 and EN ISO 1461.
A sealed SHS 100 needs a 30 mm vent hole, not 10.Metric and imperialFillet weld calculator
Leg and throat, weld metal per metre or foot, and the wire or electrodes to buy for the length, by process.
An a6 fillet is twice the weld of a z6.UKBolt hole sizes
Normal, oversize and slotted holes for M12 to M30 bolts to EN 1090-2, with the minimum edge distances and spacings.
An M12 hole is 13 mm, not 14.USBolt hole size chart
Standard, oversized and slotted holes for 1/2 in to 1 1/2 in structural bolts, from RCSC Table 3.1, with the washers they call for.
The 1/16 in rule stops at 7/8 in.UKSteel paint calculator
Paint or powder for a list of UK sections: the area from the Blue Book tables, then litres or kilograms by coats and method.
A tonne of steel can be 2.2 m² of paint, or 68.UKStair calculator
Risers, going, pitch and 2R + G for a floor-to-floor height, the flights and landings, the stairwell opening and the handrails, checked against Approved Document K.
At a 220 mm rise, a private stair's going has 16 mm of room.UKSpiral and curved stair calculator
Treads a turn, the going on the line it is measured on, the narrow end and the headroom under the turn above, for spiral, helical and curved stairs.
Under 1 m wide, a tapered tread is measured on its centre line.UKRamp gradient calculator
Flights, landings and overall length for a ramp of any rise, checked against Approved Documents M and K, or the gentlest gradient that fits the space.
At 1:12 a ramp flight may run only 2 m.UKBalustrade height checker
The guarding height for the building and the place, whether guarding is needed at that drop, and the 100 mm sphere, from Approved Document K.
The 600 mm rule is for homes only.Metric and imperialPost hole concrete calculator
Concrete for fence and gate posts: the hole less the post, in litres and 20 kg bags of Postcrete or concrete mix, with the hole checked against the makers' guidance.
Postcrete is for gates under 1 m wide.Metric and imperialTap drill size chart
The drill for every metric coarse and fine thread from M1.6 to M42, for cutting and forming taps, with the thread depth it leaves.
A forming tap needs a bigger hole than a cutting tap.Metric and imperialmm to inches converter
Millimetres to inch fractions to 1/64, feet and inches, kilograms to pounds, and a chain of dimensions converted without the rounding creeping.
Round the running total, not each dimension.UKSteel cost calculator
Price a list of sections by the stock bars you will actually buy: nested section by section with the saw cut, at your price a kilogram, with the extras.
You pay for the bar, not the piece.USADA ramp slope calculator
Runs, landings and overall length for a ramp of any rise under the 2010 ADA Standards, or the gentlest slope that fits the space.
Under the ADA a ramp run is limited by its rise, not its length.On iLuvFreeTools, our sister site
- Metal weight calculatorAny metal by its dimensions: hex bar, tube, angle, with galvanising.
- Section propertiesEvery UK UB, UC and PFC with the depth the serial size does not give you.
- Wide flange beam sizesEvery W, HP, S, C and MC shape, and why the number is not the depth.
- Steel grade referenceS275, S355, A36 and A992 side by side.
- Staircase calculatorRise, going and pitch, including the combination the table quietly forbids.
- Timber quantity and cut listThe same saw-cut logic for timber boards.