Tools/Stairs and ramps/Stair calculator
Stair calculator
Type the height from floor to floor and the stair's category: the risers, a going that works, the pitch and 2R + G, the flights and landings a general access stair needs, the stairwell opening for 2 m of headroom and the handrail heights, each checked against Approved Document K.
Private: a stair in one home. Utility: escape, maintenance or any stair that is not the usual way between floors. General access: the everyday stair in any other building, and the common stair in a block of flats.
| Category | Rise | Going |
|---|---|---|
| Private stair | 150 to 220 | 220 to 300 |
| Utility stair | 150 to 190 | 250 to 400 |
| General access stair | 150 to 170 | 250 to 400 |
The calculator needs JavaScript, which is switched off or still loading. Everything else on this page reads without it.
Next step
- Have the stair drawnOur balustrade and stair design pack sets out every flight from your photos and sizes, with the fixings and the Part K checks.See the design pack
- The rules in plain wordsRise, going, headroom, handrails and guarding for UK stairs, with the paragraph for each.Read the guide
Written for England, to Approved Document K (2013 edition). A curved or spiral stair? Use the spiral and curved stair calculator.
Worth knowing
At a 220 mm rise, a private stair's going has 16 mm of room.
Table 1.1 of Approved Document K allows a private stair a rise of up to 220 mm and a going of 220 to 300 mm, which looks like plenty. Two notes under the table close it down. The pitch of a private stair may not pass 42°, and at a 220 mm rise that needs a going of at least 245 mm (220 / tan 42° = 244.3 mm). Twice the rise plus the going must stay between 550 and 700 mm, so the going can be no more than 700 − 440 = 260 mm. A stair at the maximum rise has a going between 245 and 260 mm: 220 to 244 mm is too steep, 261 to 300 mm breaks 2R + G. The calculator works this window out for every rise.
Source: Approved Document K, 2013 edition, Table 1.1 and its notes (GOV.UK), checked on the page.
How it works
The arithmetic, the data it uses and where it stops.
Choose the category. A private stair serves one home. A utility stair is for escape, maintenance or any purpose other than the usual way between floors. A general access stair is the everyday stair in any other building, and the common stair in a block of flats. Type the height from finished floor to finished floor: the top of the floor finish, not the structural slab, because every rise is an equal share of it.
With the risers left blank the calculator takes the fewest that keep each rise inside the category's limit: 2,600 mm in a home is 12 risers of 216.7 mm. It then works the goings Table 1.1 allows at that rise: the category's range, narrowed by 2R + G between 550 and 700 mm and, for a private stair, by the 42° pitch. With the going left blank it suggests one that brings 2R + G to 625 mm, or the middle of the window when that falls outside it. Type your own figures to check a design.
A utility stair may have no more than 16 risers in a flight and a general access stair 12 (Approved Document K para 1.18), so a 3,000 mm storey in an office is 18 risers in two flights of 9, with a landing between them at least 1,200 mm long (para 1.23). Any stair with more than 36 risers in a row needs a change of direction (para 1.17).
Headroom is 2 m above the pitch line (Diagram 1.3). For the floor above, the stairwell opening has to run far enough back from the top nosing for the pitch line to be 2 m below the floor's underside: (2,000 + the floor depth) × going / rise. The calculator gives that length; check it against the joists or the slab, and against any beam that crosses the stair lower down.
The checks are Approved Document K's, 2013 edition, read on the page: rise, going, 2R + G, pitch, risers in a flight, widths outside homes (1,200 mm between walls, para 1.15) and handrails 900 to 1,000 mm above the pitch line (para 1.34). Loft conversions, alternating tread stairs, stepped gangways and industrial stairs have rules of their own in the same document, and spiral and helical stairs go to BS 5395-2.
Questions
What is the maximum rise of a stair in a house?
220 mm for a private stair, with a going of at least 220 mm, a pitch no steeper than 42° and 2R + G between 550 and 700 mm (Approved Document K, Table 1.1). The pitch rule means a 220 mm rise needs a going of 245 mm or more.
What is the 2R + G rule?
Twice the rise plus the going should be between 550 and 700 mm. It keeps each step in proportion with a stride: a 170 mm rise takes a going of 210 to 360 mm by this rule, cut back further by the category's own going limits.
How many risers can a flight have?
In a home there is no limit to a flight, but more than 36 risers in a row need a change of direction (para 1.17). Outside homes and in the common parts of flats, a utility stair may have 16 risers in a flight and a general access stair 12, or exceptionally 16 in small premises where the plan area is restricted (para 1.18).
How much headroom does a stair need?
2 m, measured vertically above the pitch line and above landings (Approved Document K, Diagram 1.3). A loft conversion without the space can have 1.9 m at the centre of the stair and 1.8 m at its side (Diagram 1.4).
Can a stair have open risers?
In a home, yes, if the treads overlap by at least 16 mm and a 100 mm sphere cannot pass through the open risers (para 1.9). In other buildings, risers should not be open (para 1.6).
How high should a stair handrail be?
900 to 1,000 mm above the pitch line or the floor (para 1.34). Stairs 1 m or wider need one on both sides; outside homes, both sides of every flight and landing, carried 300 mm past the top and bottom nosings (Diagram 1.12).
More free tools
Calculators for buying, cutting and fitting steel.
Steel weight calculator
UB, UC, PFC, angles, hot and cold hollow sections, bars and plate, from the BS EN tables. Build a list and get the total.
Hot-finished and cold-formed SHS do not weigh the same.USSteel weight per foot calculator
Every W, HP, S, C, MC, angle, HSS and pipe in the AISC Shapes Database, plus bar and plate, in pounds per foot.
An HSS weighs more than its listed area says.Metric and imperialCutting list optimiser
Nest cut lengths into 6 m, 7.5 m, 20 ft or 24 ft bars with the saw cut allowed for, searched for the fewest bars.
Longest-first can buy a bar you do not need.UK and USBaluster spacing calculator
Equal gaps between posts under the 100 mm sphere (UK) or the 4 in sphere (US), with every bar set out.
On a stair, the UK and US rules part company.Metric and imperialPlate weight calculator
Rectangles, discs and rings with holes, in steel, stainless or aluminium: the weight to lift and the plate it is cut from.
A disc is 78.5% of the plate it is cut from.Metric and imperialGate weight and hinge load calculator
The leaf weight from its frame and bars, the centre of gravity, and the pull on the top hinge.
The top hinge carries more than the gate weighs.Metric and imperialBend allowance calculator
The flat blank for a folded part from its legs, angles and thickness, with the radius the die will really give and every bend line set out.
On a press brake the die sets the radius, not the drawing.UK and USSheet metal gauge chart
Gauge to millimetres and back in the UK Standard Wire Gauge and the US steel, galvanized, stainless and aluminium tables, side by side.
16 gauge is five different thicknesses.UKGalvanising calculator
Vent and drain holes for sealed hollow sections, and the zinc a part picks up, to EN ISO 14713-2 and EN ISO 1461.
A sealed SHS 100 needs a 30 mm vent hole, not 10.Metric and imperialFillet weld calculator
Leg and throat, weld metal per metre or foot, and the wire or electrodes to buy for the length, by process.
An a6 fillet is twice the weld of a z6.UKBolt hole sizes
Normal, oversize and slotted holes for M12 to M30 bolts to EN 1090-2, with the minimum edge distances and spacings.
An M12 hole is 13 mm, not 14.USBolt hole size chart
Standard, oversized and slotted holes for 1/2 in to 1 1/2 in structural bolts, from RCSC Table 3.1, with the washers they call for.
The 1/16 in rule stops at 7/8 in.UKSteel paint calculator
Paint or powder for a list of UK sections: the area from the Blue Book tables, then litres or kilograms by coats and method.
A tonne of steel can be 2.2 m² of paint, or 68.UKSpiral and curved stair calculator
Treads a turn, the going on the line it is measured on, the narrow end and the headroom under the turn above, for spiral, helical and curved stairs.
Under 1 m wide, a tapered tread is measured on its centre line.UKRamp gradient calculator
Flights, landings and overall length for a ramp of any rise, checked against Approved Documents M and K, or the gentlest gradient that fits the space.
At 1:12 a ramp flight may run only 2 m.UKBalustrade height checker
The guarding height for the building and the place, whether guarding is needed at that drop, and the 100 mm sphere, from Approved Document K.
The 600 mm rule is for homes only.Metric and imperialPost hole concrete calculator
Concrete for fence and gate posts: the hole less the post, in litres and 20 kg bags of Postcrete or concrete mix, with the hole checked against the makers' guidance.
Postcrete is for gates under 1 m wide.Metric and imperialTap drill size chart
The drill for every metric coarse and fine thread from M1.6 to M42, for cutting and forming taps, with the thread depth it leaves.
A forming tap needs a bigger hole than a cutting tap.Metric and imperialmm to inches converter
Millimetres to inch fractions to 1/64, feet and inches, kilograms to pounds, and a chain of dimensions converted without the rounding creeping.
Round the running total, not each dimension.UKSteel cost calculator
Price a list of sections by the stock bars you will actually buy: nested section by section with the saw cut, at your price a kilogram, with the extras.
You pay for the bar, not the piece.USADA ramp slope calculator
Runs, landings and overall length for a ramp of any rise under the 2010 ADA Standards, or the gentlest slope that fits the space.
Under the ADA a ramp run is limited by its rise, not its length.On iLuvFreeTools, our sister site
- Metal weight calculatorAny metal by its dimensions: hex bar, tube, angle, with galvanising.
- Section propertiesEvery UK UB, UC and PFC with the depth the serial size does not give you.
- Wide flange beam sizesEvery W, HP, S, C and MC shape, and why the number is not the depth.
- Steel grade referenceS275, S355, A36 and A992 side by side.
- Staircase calculatorRise, going and pitch, including the combination the table quietly forbids.
- Timber quantity and cut listThe same saw-cut logic for timber boards.