Tools/Galvanising and painting/Galvanising calculator
Galvanising calculator: vent holes and zinc
The vent and drain holes a sealed hollow section needs before it goes in the bath, read from the EN ISO 14713-2 table, and the zinc it will pick up at the EN ISO 1461 minimum, by the thickness of the steel.
Vent and drain holes
Zinc
The calculator needs JavaScript, which is switched off or still loading. Everything else on this page reads without it.
Next step
- Get it drawnFabrication drawings with the vent holes drawn and dimensioned on every sealed section and the galvanising note on every sheet. A fixed price within four hours.Price the drawings
- Painting as well?Work the area and the paint or powder for the same steel, from the section tables.Open the paint calculator
Written to the standards used in the UK and Europe: EN ISO 1461 for the coating and EN ISO 14713-2 for venting. US work is galvanized to ASTM A123, with its own coating grades and venting guidance, which this page does not cover.
Worth knowing
A sealed SHS 100 needs a 30 mm vent hole, not 10.
A hollow section closed at its ends has to be vented and drained at each end before it is dipped in zinc at 450°C: for safety, so the air can get out, and so the zinc can get in and drain away. The hole people quote is 10 mm, the smallest the guidance allows, and in the EN ISO 14713-2 table 10 mm is the hole for a 15 or 20 mm tube. The hole grows with the section. One hole at each end of an SHS 100 must be 30 mm, of an SHS 200 60 mm, and from 300 mm the table has no single-hole option at all: two holes of 60 mm at each end, or more and smaller. Under-size them and the zinc cannot flow in and out freely, which costs the coating and the galvaniser's time.
Source: EN ISO 14713-2:2020 Table 1, guidance on vent hole sizes for hollow sections, as reproduced in the Galvanizers Association's 'Design for Galvanizing' poster; GA HDG Datasheet 18, venting and drainage (galvanizing.org.uk).
How it works
The arithmetic, the data it uses and where it stops.
For the vent holes, choose square or rectangular, or round, and type the size. The tool reads the first row of EN ISO 14713-2 Table 1 that holds your section: a 101.6 CHS, bigger than the 100 row, takes the 120 row; a 300 x 200 RHS takes the 350 x 250 row. It shows one, two and four holes at each end, and the corner crops and centre-hole layouts the table also gives for that size.
The table's notes matter. With one or two holes, the far end's sit diagonally opposite the near end's; a crop's size is the length of its side, not its diagonal; and holes go as near the wall as practicable (GA Datasheet 18). The guidance is for sealed sections with no venting along their length. On a fabrication, open mitred joints and internal holes vent members into each other, and the galvaniser's word decides.
For the zinc, type the steel thickness and, if you want weights, the steel weight. EN ISO 1461 sets a minimum mean coating by the thickness of the steel: 85 µm over 6 mm, 70 µm over 3 mm up to 6, 55 µm from 1.5 to 3 mm and 45 µm under 1.5 mm (Table 3, work not centrifuged), with a lower local figure no single test area may fall below. Centrifuged small parts and threaded parts have their own, thinner figures (Table 4).
Microns become grams with the coating density the standard itself uses, 7.2 g/cm³: 85 µm is 612 g/m² a face (ISO 1461 tabulates 610). A part of uniform thickness t mm has 2 / (7.85 t) square metres of surface for every kilogram, counting both faces; a hollow section is dipped inside and out, so the same holds. The zinc is that area times the coating mass.
These are minimums. Coatings grow thicker on reactive steels, those with more silicon (the Galvanizers Association gives typically over 0.25%), and on steel well over 6 mm thick a coating over 140 µm will normally be achieved (GA Datasheet 4a). A weighbridge will usually show more zinc than the minimum, so treat the weight gain as a floor.
Questions
What size vent holes do I need for galvanising?
It depends on the section. For one hole at each end: 10 mm for a 20 mm tube, 16 mm for 50 mm square, 20 mm for 60, 25 for 80, 30 for 100, 45 for 160 and 60 mm for 200 mm square (EN ISO 14713-2 Table 1). Two or four smaller holes at each end can do the same job.
Where should vent holes go?
At each end of every sealed section, as near the wall as practicable, with the holes at one end diagonally opposite those at the other. In end plates, off centre and close to the wall of the member the plate is welded to (GA Datasheet 18).
How much weight does galvanising add?
At the EN ISO 1461 minimum, about 1.6% on 10 mm steel, 3.4% on 3 mm and 6.7% on 1.5 mm, because the zinc goes on by area and thin steel has more area to the kilogram. Real coatings are usually thicker than the minimum, so allow more.
How thick is a hot-dip galvanized coating?
EN ISO 1461 sets a minimum mean of 85 µm on steel over 6 mm thick, 70 µm over 3 up to 6 mm, 55 µm from 1.5 to 3 mm and 45 µm under 1.5 mm. On steel well over 6 mm, coatings over 140 µm are normal (GA Datasheet 4a).
Can a sealed tube be galvanised?
Not safely. Hollow sections that are sealed must be vented, for safety and so the zinc can get in and drain (GA Datasheet 18). Every closed end needs its holes, or the end left open.
More free tools
Calculators for buying, cutting and fitting steel.
Steel weight calculator
UB, UC, PFC, angles, hot and cold hollow sections, bars and plate, from the BS EN tables. Build a list and get the total.
Hot-finished and cold-formed SHS do not weigh the same.USSteel weight per foot calculator
Every W, HP, S, C, MC, angle, HSS and pipe in the AISC Shapes Database, plus bar and plate, in pounds per foot.
An HSS weighs more than its listed area says.Metric and imperialCutting list optimiser
Nest cut lengths into 6 m, 7.5 m, 20 ft or 24 ft bars with the saw cut allowed for, searched for the fewest bars.
Longest-first can buy a bar you do not need.UK and USBaluster spacing calculator
Equal gaps between posts under the 100 mm sphere (UK) or the 4 in sphere (US), with every bar set out.
On a stair, the UK and US rules part company.Metric and imperialPlate weight calculator
Rectangles, discs and rings with holes, in steel, stainless or aluminium: the weight to lift and the plate it is cut from.
A disc is 78.5% of the plate it is cut from.Metric and imperialGate weight and hinge load calculator
The leaf weight from its frame and bars, the centre of gravity, and the pull on the top hinge.
The top hinge carries more than the gate weighs.Metric and imperialBend allowance calculator
The flat blank for a folded part from its legs, angles and thickness, with the radius the die will really give and every bend line set out.
On a press brake the die sets the radius, not the drawing.UK and USSheet metal gauge chart
Gauge to millimetres and back in the UK Standard Wire Gauge and the US steel, galvanized, stainless and aluminium tables, side by side.
16 gauge is five different thicknesses.Metric and imperialFillet weld calculator
Leg and throat, weld metal per metre or foot, and the wire or electrodes to buy for the length, by process.
An a6 fillet is twice the weld of a z6.UKBolt hole sizes
Normal, oversize and slotted holes for M12 to M30 bolts to EN 1090-2, with the minimum edge distances and spacings.
An M12 hole is 13 mm, not 14.USBolt hole size chart
Standard, oversized and slotted holes for 1/2 in to 1 1/2 in structural bolts, from RCSC Table 3.1, with the washers they call for.
The 1/16 in rule stops at 7/8 in.UKSteel paint calculator
Paint or powder for a list of UK sections: the area from the Blue Book tables, then litres or kilograms by coats and method.
A tonne of steel can be 2.2 m² of paint, or 68.UKStair calculator
Risers, going, pitch and 2R + G for a floor-to-floor height, the flights and landings, the stairwell opening and the handrails, checked against Approved Document K.
At a 220 mm rise, a private stair's going has 16 mm of room.UKSpiral and curved stair calculator
Treads a turn, the going on the line it is measured on, the narrow end and the headroom under the turn above, for spiral, helical and curved stairs.
Under 1 m wide, a tapered tread is measured on its centre line.UKRamp gradient calculator
Flights, landings and overall length for a ramp of any rise, checked against Approved Documents M and K, or the gentlest gradient that fits the space.
At 1:12 a ramp flight may run only 2 m.UKBalustrade height checker
The guarding height for the building and the place, whether guarding is needed at that drop, and the 100 mm sphere, from Approved Document K.
The 600 mm rule is for homes only.Metric and imperialPost hole concrete calculator
Concrete for fence and gate posts: the hole less the post, in litres and 20 kg bags of Postcrete or concrete mix, with the hole checked against the makers' guidance.
Postcrete is for gates under 1 m wide.Metric and imperialTap drill size chart
The drill for every metric coarse and fine thread from M1.6 to M42, for cutting and forming taps, with the thread depth it leaves.
A forming tap needs a bigger hole than a cutting tap.Metric and imperialmm to inches converter
Millimetres to inch fractions to 1/64, feet and inches, kilograms to pounds, and a chain of dimensions converted without the rounding creeping.
Round the running total, not each dimension.UKSteel cost calculator
Price a list of sections by the stock bars you will actually buy: nested section by section with the saw cut, at your price a kilogram, with the extras.
You pay for the bar, not the piece.USADA ramp slope calculator
Runs, landings and overall length for a ramp of any rise under the 2010 ADA Standards, or the gentlest slope that fits the space.
Under the ADA a ramp run is limited by its rise, not its length.On iLuvFreeTools, our sister site
- Metal weight calculatorAny metal by its dimensions: hex bar, tube, angle, with galvanising.
- Section propertiesEvery UK UB, UC and PFC with the depth the serial size does not give you.
- Wide flange beam sizesEvery W, HP, S, C and MC shape, and why the number is not the depth.
- Steel grade referenceS275, S355, A36 and A992 side by side.
- Staircase calculatorRise, going and pitch, including the combination the table quietly forbids.
- Timber quantity and cut listThe same saw-cut logic for timber boards.