Basket07399 358543

Tools/Balustrades, railings and gates/Baluster spacing calculator

Baluster and spindle spacing calculator

Equal gaps between two posts that a 100 mm sphere cannot pass (UK, Approved Document K) or a 4 in sphere (US, IRC R312.1.3): the fewest bars, the gap, the centres and every bar set out from the post.

Rules
Where
I have

UK: a 100 mm sphere must not pass any opening (Approved Document K, paras 1.39a and 3.3a).

The calculator needs JavaScript, which is switched off or still loading. Everything else on this page reads without it.

Covers the UK (Approved Document K, England) and the US (International Residential Code). Switch the market inside the tool; the rules and the units change with it.

Worth knowing

On a stair, the UK and US rules part company.

On a landing, a balcony or a deck the two rules are close: the UK's 100 mm sphere and the US's 4 in, which is 101.6 mm. On the open side of a stair they part. Approved Document K applies the same 100 mm sphere to the guarding of a flight (para 1.39a), so a UK stair is spaced like a landing. The IRC lets a 4 3/8 in sphere (111 mm) through a guard on the open side of a stair, and 6 in (153 mm) through the triangle formed by the riser, the tread and the bottom rail (R312.1.3, exceptions 1 and 2). A US stair rail spaced to the UK rule uses more balusters than it needs; a UK stair spaced to the American one fails.

Source: Approved Document K, 2013 edition, paras 1.39a and 3.3a (GOV.UK); International Residential Code R312.1.3 and its exceptions, as quoted in New York State Department of State Technical Bulletin TB-1005 (dos.ny.gov).

How it works

The arithmetic, the data it uses and where it stops.

Choose the UK or the US rule and where the guarding is, then type the distance between the posts (the clear gap between their faces, or their centres and the post size), the width of one bar across the run, and the allowance you want to keep under the rule for site tolerance.

With n bars between two posts there are n + 1 gaps, each (distance − n × bar width) / (n + 1). The calculator finds the fewest bars that bring that gap under the limit, then gives the gap, the bar centres (gap plus bar width) and each bar's centre measured from the first post face, ready to mark out. It also shows what one bar fewer would leave, so you can see why the count is what it is.

With no allowance the gap is kept strictly under the sphere, because the rules say the sphere must not pass: a 100 mm gap lets a 100 mm sphere through. We set our own balustrades out at 95 mm clear, which keeps 5 mm for the bars that are fixed a little out on site; that is the default here.

The rule is about the sphere and every opening it could pass, not only the gaps between bars. Check the gap under the bottom rail, the gap at each post and, on a stair, the triangle under the bottom rail, with the same sphere.

In the UK, Approved Document K applies the 100 mm sphere where a building may be used by children under five, and asks that guarding there is not easy to climb, which is why it says to avoid horizontal rails. In the US the IRC rule applies to required guards in houses; commercial buildings come under the IBC, and local codes can amend either.

Questions

Is the 100 mm rule the gap or the centres?

The gap. The rule is that a 100 mm sphere must not pass through any opening, so it is the clear space between the bars. Bar centres are the gap plus the bar width: 16 mm bars at 95 mm clear are at 111 mm centres.

What is the 4 inch sphere rule?

The IRC rule that required guards must not have openings a 4 in sphere can pass through, from the walking surface up to the required guard height (R312.1.3). On the open side of a stair the limit is 4 3/8 in, and 6 in in the triangle under the bottom rail.

Does the sphere rule apply under the bottom rail?

Yes. Approved Document K says the sphere should not pass through any openings in the guarding, which includes the gap between the floor or the stair and the bottom rail, and the gap beside each post.

How do I space bars evenly between posts?

Work out how many bars bring the gap under the limit, then divide what is left equally. With n bars there are n + 1 gaps: gap = (distance minus n times bar width) / (n + 1). The calculator does this and lists every bar's centre from the post face.

Can I use horizontal bars?

In the UK, Approved Document K says to avoid horizontal rails where a building may be used by children under five, because they can be climbed. Vertical bars are the usual answer for homes.

More free tools

Calculators for buying, cutting and fitting steel.

UK

Steel weight calculator

UB, UC, PFC, angles, hot and cold hollow sections, bars and plate, from the BS EN tables. Build a list and get the total.

Hot-finished and cold-formed SHS do not weigh the same.
US

Steel weight per foot calculator

Every W, HP, S, C, MC, angle, HSS and pipe in the AISC Shapes Database, plus bar and plate, in pounds per foot.

An HSS weighs more than its listed area says.
Metric and imperial

Cutting list optimiser

Nest cut lengths into 6 m, 7.5 m, 20 ft or 24 ft bars with the saw cut allowed for, searched for the fewest bars.

Longest-first can buy a bar you do not need.
Metric and imperial

Plate weight calculator

Rectangles, discs and rings with holes, in steel, stainless or aluminium: the weight to lift and the plate it is cut from.

A disc is 78.5% of the plate it is cut from.
Metric and imperial

Gate weight and hinge load calculator

The leaf weight from its frame and bars, the centre of gravity, and the pull on the top hinge.

The top hinge carries more than the gate weighs.
Metric and imperial

Bend allowance calculator

The flat blank for a folded part from its legs, angles and thickness, with the radius the die will really give and every bend line set out.

On a press brake the die sets the radius, not the drawing.
UK and US

Sheet metal gauge chart

Gauge to millimetres and back in the UK Standard Wire Gauge and the US steel, galvanized, stainless and aluminium tables, side by side.

16 gauge is five different thicknesses.
UK

Galvanising calculator

Vent and drain holes for sealed hollow sections, and the zinc a part picks up, to EN ISO 14713-2 and EN ISO 1461.

A sealed SHS 100 needs a 30 mm vent hole, not 10.
Metric and imperial

Fillet weld calculator

Leg and throat, weld metal per metre or foot, and the wire or electrodes to buy for the length, by process.

An a6 fillet is twice the weld of a z6.
UK

Bolt hole sizes

Normal, oversize and slotted holes for M12 to M30 bolts to EN 1090-2, with the minimum edge distances and spacings.

An M12 hole is 13 mm, not 14.
US

Bolt hole size chart

Standard, oversized and slotted holes for 1/2 in to 1 1/2 in structural bolts, from RCSC Table 3.1, with the washers they call for.

The 1/16 in rule stops at 7/8 in.
UK

Steel paint calculator

Paint or powder for a list of UK sections: the area from the Blue Book tables, then litres or kilograms by coats and method.

A tonne of steel can be 2.2 m² of paint, or 68.
UK

Stair calculator

Risers, going, pitch and 2R + G for a floor-to-floor height, the flights and landings, the stairwell opening and the handrails, checked against Approved Document K.

At a 220 mm rise, a private stair's going has 16 mm of room.
UK

Spiral and curved stair calculator

Treads a turn, the going on the line it is measured on, the narrow end and the headroom under the turn above, for spiral, helical and curved stairs.

Under 1 m wide, a tapered tread is measured on its centre line.
UK

Ramp gradient calculator

Flights, landings and overall length for a ramp of any rise, checked against Approved Documents M and K, or the gentlest gradient that fits the space.

At 1:12 a ramp flight may run only 2 m.
UK

Balustrade height checker

The guarding height for the building and the place, whether guarding is needed at that drop, and the 100 mm sphere, from Approved Document K.

The 600 mm rule is for homes only.
Metric and imperial

Post hole concrete calculator

Concrete for fence and gate posts: the hole less the post, in litres and 20 kg bags of Postcrete or concrete mix, with the hole checked against the makers' guidance.

Postcrete is for gates under 1 m wide.
Metric and imperial

Tap drill size chart

The drill for every metric coarse and fine thread from M1.6 to M42, for cutting and forming taps, with the thread depth it leaves.

A forming tap needs a bigger hole than a cutting tap.
Metric and imperial

mm to inches converter

Millimetres to inch fractions to 1/64, feet and inches, kilograms to pounds, and a chain of dimensions converted without the rounding creeping.

Round the running total, not each dimension.
UK

Steel cost calculator

Price a list of sections by the stock bars you will actually buy: nested section by section with the saw cut, at your price a kilogram, with the extras.

You pay for the bar, not the piece.
US

ADA ramp slope calculator

Runs, landings and overall length for a ramp of any rise under the 2010 ADA Standards, or the gentlest slope that fits the space.

Under the ADA a ramp run is limited by its rise, not its length.

On iLuvFreeTools, our sister site