The area of a list of UK steel sections from the published tables, and the paint or powder to cover it: litres by volume solids, film thickness, coats and how it goes on, or kilograms of powder by specific gravity and film.

Coating
SectionLength mmQtym²Remove

The calculator needs JavaScript, which is switched off or still loading. Everything else on this page reads without it.

Written for UK sections, from the Blue Book's surface areas, in metric. The paint arithmetic works anywhere: for other sections, type the area in Other area.

Worth knowing

A tonne of steel can be 2.2 m² of paint, or 68.

Steel is bought and weighed by the tonne, and the area in a tonne swings enormously. The Blue Book tables give every section's outside surface per metre: a tonne of UC 356x406x1299 is 2.2 m², a tonne of UB 914x419x388 8.9 m², of UB 203x133x25 36 m², and of cold-formed SHS 25x25x2 68 m², thirty times the heaviest column. Paint goes on by area. A price per tonne that suits a frame of heavy beams loses money on a job of light tube, and overcharges the other way. Work the area from the sections, then the paint from the area.

Source: Steel for Life Blue Book section tables: surface area per metre divided by mass per metre, for UB, UC, PFC and hot-finished and cold-formed SHS, RHS and CHS (steelforlifebluebook.co.uk).

How it works

The arithmetic, the data it uses and where it stops.

Pick each section and size, type its length in millimetres and how many, and add it to the list: its area is the table's surface per metre times the length. The list covers the sections the Blue Book gives a surface area for (UB, UC, PFC and hot-finished and cold-formed SHS, RHS and CHS); type the area of plates, angles and anything else in Other area. The area is the outside of each member, which is what gets painted.

For liquid paint, type the volume solids and the dry film thickness a coat from the product data sheet, and the number of coats. The theoretical spreading rate is volume solids x 10 / dry film thickness, in square metres a litre: 55% solids at 75 µm is 7.33 m²/L. Hempel defines it on a completely smooth surface with no losses, and lists what makes real consumption higher: rough steel, weld seams, uneven film, the shape and size of the work, and paint left in tins, pumps and hoses.

The practical rate is the theoretical one times a coverage efficiency for the surface and the method. The tool uses Wattyl's published figures for blast-cleaned steel: 0.83 by brush or roller, 0.74 by airless spray inside, 0.65 outside and 0.46 in wind. They are one paint maker's figures, so use your painter's own if they have them.

For powder, type the specific gravity and film thickness from the data sheet. The theoretical coverage is 1,000 / (SG x film in µm) square metres a kilogram: SG 1.5 at 70 µm is 9.5 m²/kg. That assumes every gram ends up on the steel; type your coater's transfer figure to see what they will really use, since the powder makers' coverage charts give only the theoretical number.

The area per tonne under the result shows what the list holds: set it against any price per tonne before you accept one. Primers, stripe coats on edges and welds, and the number of coats are the painter's specification; the tool works whatever coats you give it.

Questions

How do I work out the surface area of steel for painting?

Multiply each section's surface area per metre by its length. The Blue Book tables give it for every UB, UC, PFC and hollow section: a UB 203x133x25 is 0.915 m² a metre, so a 6 m length is 5.5 m².

How much paint do I need for a tonne of steel?

It depends on the sections: a tonne is 2.2 m² of the heaviest UC and 68 m² of a light SHS. Work the area first. At 55% solids and 75 µm a coat, a litre covers 7.33 m² in theory and about 4.8 m² sprayed outside on blast-cleaned steel.

What is the spreading rate of paint?

The theoretical spreading rate is volume solids % x 10 / dry film thickness in µm, in square metres a litre (Hempel). The practical rate is less: the theoretical rate times a coverage efficiency for the surface and the method.

How far does a kilogram of powder coating go?

1,000 / (specific gravity x film thickness in µm) square metres, in theory: SG 1.5 at 70 µm is 9.5 m²/kg, SG 1.6 at 75 µm is 8.3. The real figure depends on how much overspray your coater recovers.

Does the area include the inside of hollow sections?

No. The tables give the outside surface, the area that is painted. Galvanizing coats the inside as well, which is why the galvanising calculator works from the steel's thickness instead.

More free tools

Calculators for buying, cutting and fitting steel.

UK

Steel weight calculator

UB, UC, PFC, angles, hot and cold hollow sections, bars and plate, from the BS EN tables. Build a list and get the total.

Hot-finished and cold-formed SHS do not weigh the same.
US

Steel weight per foot calculator

Every W, HP, S, C, MC, angle, HSS and pipe in the AISC Shapes Database, plus bar and plate, in pounds per foot.

An HSS weighs more than its listed area says.
Metric and imperial

Cutting list optimiser

Nest cut lengths into 6 m, 7.5 m, 20 ft or 24 ft bars with the saw cut allowed for, searched for the fewest bars.

Longest-first can buy a bar you do not need.
UK and US

Baluster spacing calculator

Equal gaps between posts under the 100 mm sphere (UK) or the 4 in sphere (US), with every bar set out.

On a stair, the UK and US rules part company.
Metric and imperial

Plate weight calculator

Rectangles, discs and rings with holes, in steel, stainless or aluminium: the weight to lift and the plate it is cut from.

A disc is 78.5% of the plate it is cut from.
Metric and imperial

Gate weight and hinge load calculator

The leaf weight from its frame and bars, the centre of gravity, and the pull on the top hinge.

The top hinge carries more than the gate weighs.
Metric and imperial

Bend allowance calculator

The flat blank for a folded part from its legs, angles and thickness, with the radius the die will really give and every bend line set out.

On a press brake the die sets the radius, not the drawing.
UK and US

Sheet metal gauge chart

Gauge to millimetres and back in the UK Standard Wire Gauge and the US steel, galvanized, stainless and aluminium tables, side by side.

16 gauge is five different thicknesses.
UK

Galvanising calculator

Vent and drain holes for sealed hollow sections, and the zinc a part picks up, to EN ISO 14713-2 and EN ISO 1461.

A sealed SHS 100 needs a 30 mm vent hole, not 10.
Metric and imperial

Fillet weld calculator

Leg and throat, weld metal per metre or foot, and the wire or electrodes to buy for the length, by process.

An a6 fillet is twice the weld of a z6.
UK

Bolt hole sizes

Normal, oversize and slotted holes for M12 to M30 bolts to EN 1090-2, with the minimum edge distances and spacings.

An M12 hole is 13 mm, not 14.
US

Bolt hole size chart

Standard, oversized and slotted holes for 1/2 in to 1 1/2 in structural bolts, from RCSC Table 3.1, with the washers they call for.

The 1/16 in rule stops at 7/8 in.
UK

Stair calculator

Risers, going, pitch and 2R + G for a floor-to-floor height, the flights and landings, the stairwell opening and the handrails, checked against Approved Document K.

At a 220 mm rise, a private stair's going has 16 mm of room.
UK

Spiral and curved stair calculator

Treads a turn, the going on the line it is measured on, the narrow end and the headroom under the turn above, for spiral, helical and curved stairs.

Under 1 m wide, a tapered tread is measured on its centre line.
UK

Ramp gradient calculator

Flights, landings and overall length for a ramp of any rise, checked against Approved Documents M and K, or the gentlest gradient that fits the space.

At 1:12 a ramp flight may run only 2 m.
UK

Balustrade height checker

The guarding height for the building and the place, whether guarding is needed at that drop, and the 100 mm sphere, from Approved Document K.

The 600 mm rule is for homes only.
Metric and imperial

Post hole concrete calculator

Concrete for fence and gate posts: the hole less the post, in litres and 20 kg bags of Postcrete or concrete mix, with the hole checked against the makers' guidance.

Postcrete is for gates under 1 m wide.
Metric and imperial

Tap drill size chart

The drill for every metric coarse and fine thread from M1.6 to M42, for cutting and forming taps, with the thread depth it leaves.

A forming tap needs a bigger hole than a cutting tap.
Metric and imperial

mm to inches converter

Millimetres to inch fractions to 1/64, feet and inches, kilograms to pounds, and a chain of dimensions converted without the rounding creeping.

Round the running total, not each dimension.
UK

Steel cost calculator

Price a list of sections by the stock bars you will actually buy: nested section by section with the saw cut, at your price a kilogram, with the extras.

You pay for the bar, not the piece.
US

ADA ramp slope calculator

Runs, landings and overall length for a ramp of any rise under the 2010 ADA Standards, or the gentlest slope that fits the space.

Under the ADA a ramp run is limited by its rise, not its length.

On iLuvFreeTools, our sister site