Basket07399 358543

Tools/Balustrades, railings and gates/Balustrade height checker

Balustrade height checker

Pick the building and where the guarding goes: the height Approved Document K asks for, whether guarding is needed at that drop, the handrail height on a flight and the 100 mm sphere, with your own figures checked against them.

Approved Document K, Diagram 3.1: guarding heights, mm. On a flight, above the pitch line
BuildingLocationHeight
Single family dwellingStairs and ramps900
Landings and edges of internal floors900
External balconies (Juliets too) and edges of roofs1100
Factory or warehouse (light traffic)Stairs and ramps900
Landings and edges of floors1100
Residential, institutional, educational, office or public buildingFlights of stairs900
Every other location1100
Assembly buildingWithin 530 mm in front of fixed seating800
Flights of stairs900
Every other location1100
RetailFlights of stairs900
Every other location1100
Every buildingBelow an opening window (not roof windows in loft extensions)800

The calculator needs JavaScript, which is switched off or still loading. Everything else on this page reads without it.

Written for England, to Approved Document K (2013 edition). Setting the bars out? Use the baluster spacing calculator.

Worth knowing

The 600 mm rule is for homes only.

Guarding is needed in a home where there is a drop of more than 600 mm, the number most people quote. Approved Document K sets a lower trigger for every other building: guarding that stops people falling more than the height of two risers, or 380 mm where the edge is not part of a stair. On the stairs and landings of those buildings, and in the common parts of a block of flats, it asks for guarding at the sides as soon as there are two risers. A 450 mm raised floor in an office, a shop or a school needs guarding; the same edge in a house does not.

Source: Approved Document K, 2013 edition, Requirement K2 performance (a) and (b) and paras 1.40 and 1.41 (GOV.UK), checked on the page.

How it works

The arithmetic, the data it uses and where it stops.

Choose the building as Approved Document K's Diagram 3.1 lists them, then the location. Single family dwellings: 900 mm on stairs, landings, ramps and the edges of internal floors, 1,100 mm on external balconies (Juliets too) and the edges of roofs. Factories and warehouses with light traffic: 900 mm on stairs and ramps, 1,100 mm on landings and floor edges. Residential, institutional, educational, office, public and retail buildings: 900 mm on flights, 1,100 mm everywhere else. Assembly buildings: 800 mm within 530 mm in front of fixed seating.

On a flight of stairs the height is measured vertically above the pitch line, the line through the nosings. The handrail goes 900 to 1,000 mm above it (para 1.34a) and may be the top of the guarding where the heights match (para 1.34b), so a 900 mm guard with its handrail at 900 to 1,000 mm is one rail, not two.

Whether guarding is needed: in a home, at a drop of more than 600 mm (para 1.41); elsewhere, from two risers on a stair (para 1.40) or a drop of more than 380 mm off one (Requirement K2). Under an opening window the guarding is 800 mm (Diagram 3.1), unless it is a roof window in a loft extension, which Approved Document B covers.

Where children under five may use the building, no opening in the guarding should let a 100 mm sphere through, and horizontal rails are to be avoided because they can be climbed (para 3.3, and para 1.39 on stairs). Type the largest opening to have it checked, the gap under the bottom rail included; the baluster spacing calculator sets the bars out.

Height and openings are half the job. Guarding must also take the loads in BS EN 1991-1-1, its UK National Annex and PD 6688-1-1 (para 3.2c), with BS 6180 as further guidance on barrier design. Those are paid standards, so this checker gives no loads: your engineer or the system's test report covers them. Glass in guarding: Approved Document K Section 5. Diagram 3.1 does not name flats; their common parts come under the residential row, and for a stair inside one flat agree the row with your building control body.

Questions

What height should a balustrade be in the UK?

900 mm on stairs and 1,100 mm on landings and balconies in most buildings. In a single family dwelling, internal landings and floor edges are 900 mm too, and external balconies and roof edges 1,100 mm (Approved Document K, Diagram 3.1).

Is a Juliet balcony 1100 mm high?

Yes. Diagram 3.1 puts external balconies, Juliette balconies included, at 1,100 mm, in a house as in any other building.

When is guarding needed?

In a home, where the drop is more than 600 mm. In other buildings and the common parts of flats, at the sides of flights and landings with two or more risers, and elsewhere where people could fall more than 380 mm (Approved Document K, Requirement K2 and paras 1.40 and 1.41).

How is the height of stair guarding measured?

Vertically from the pitch line, the line joining the nosings, to the top of the guarding. On a landing it is measured from the floor.

What is the 100 mm sphere rule?

Where a building may be used by children under five, a 100 mm sphere should not pass through any opening in the guarding (Approved Document K para 3.3a): the gaps between bars, the gap under the bottom rail and the triangle under a stair's bottom rail.

What loads must a balustrade take?

Those in BS EN 1991-1-1 with its UK National Annex and PD 6688-1-1 (Approved Document K para 3.2c), with BS 6180 as further guidance. They are paid standards and depend on the building's use, so we leave them to your engineer or the system's test report.

More free tools

Calculators for buying, cutting and fitting steel.

UK

Steel weight calculator

UB, UC, PFC, angles, hot and cold hollow sections, bars and plate, from the BS EN tables. Build a list and get the total.

Hot-finished and cold-formed SHS do not weigh the same.
US

Steel weight per foot calculator

Every W, HP, S, C, MC, angle, HSS and pipe in the AISC Shapes Database, plus bar and plate, in pounds per foot.

An HSS weighs more than its listed area says.
Metric and imperial

Cutting list optimiser

Nest cut lengths into 6 m, 7.5 m, 20 ft or 24 ft bars with the saw cut allowed for, searched for the fewest bars.

Longest-first can buy a bar you do not need.
UK and US

Baluster spacing calculator

Equal gaps between posts under the 100 mm sphere (UK) or the 4 in sphere (US), with every bar set out.

On a stair, the UK and US rules part company.
Metric and imperial

Plate weight calculator

Rectangles, discs and rings with holes, in steel, stainless or aluminium: the weight to lift and the plate it is cut from.

A disc is 78.5% of the plate it is cut from.
Metric and imperial

Gate weight and hinge load calculator

The leaf weight from its frame and bars, the centre of gravity, and the pull on the top hinge.

The top hinge carries more than the gate weighs.
Metric and imperial

Bend allowance calculator

The flat blank for a folded part from its legs, angles and thickness, with the radius the die will really give and every bend line set out.

On a press brake the die sets the radius, not the drawing.
UK and US

Sheet metal gauge chart

Gauge to millimetres and back in the UK Standard Wire Gauge and the US steel, galvanized, stainless and aluminium tables, side by side.

16 gauge is five different thicknesses.
UK

Galvanising calculator

Vent and drain holes for sealed hollow sections, and the zinc a part picks up, to EN ISO 14713-2 and EN ISO 1461.

A sealed SHS 100 needs a 30 mm vent hole, not 10.
Metric and imperial

Fillet weld calculator

Leg and throat, weld metal per metre or foot, and the wire or electrodes to buy for the length, by process.

An a6 fillet is twice the weld of a z6.
UK

Bolt hole sizes

Normal, oversize and slotted holes for M12 to M30 bolts to EN 1090-2, with the minimum edge distances and spacings.

An M12 hole is 13 mm, not 14.
US

Bolt hole size chart

Standard, oversized and slotted holes for 1/2 in to 1 1/2 in structural bolts, from RCSC Table 3.1, with the washers they call for.

The 1/16 in rule stops at 7/8 in.
UK

Steel paint calculator

Paint or powder for a list of UK sections: the area from the Blue Book tables, then litres or kilograms by coats and method.

A tonne of steel can be 2.2 m² of paint, or 68.
UK

Stair calculator

Risers, going, pitch and 2R + G for a floor-to-floor height, the flights and landings, the stairwell opening and the handrails, checked against Approved Document K.

At a 220 mm rise, a private stair's going has 16 mm of room.
UK

Spiral and curved stair calculator

Treads a turn, the going on the line it is measured on, the narrow end and the headroom under the turn above, for spiral, helical and curved stairs.

Under 1 m wide, a tapered tread is measured on its centre line.
UK

Ramp gradient calculator

Flights, landings and overall length for a ramp of any rise, checked against Approved Documents M and K, or the gentlest gradient that fits the space.

At 1:12 a ramp flight may run only 2 m.
Metric and imperial

Post hole concrete calculator

Concrete for fence and gate posts: the hole less the post, in litres and 20 kg bags of Postcrete or concrete mix, with the hole checked against the makers' guidance.

Postcrete is for gates under 1 m wide.
Metric and imperial

Tap drill size chart

The drill for every metric coarse and fine thread from M1.6 to M42, for cutting and forming taps, with the thread depth it leaves.

A forming tap needs a bigger hole than a cutting tap.
Metric and imperial

mm to inches converter

Millimetres to inch fractions to 1/64, feet and inches, kilograms to pounds, and a chain of dimensions converted without the rounding creeping.

Round the running total, not each dimension.
UK

Steel cost calculator

Price a list of sections by the stock bars you will actually buy: nested section by section with the saw cut, at your price a kilogram, with the extras.

You pay for the bar, not the piece.
US

ADA ramp slope calculator

Runs, landings and overall length for a ramp of any rise under the 2010 ADA Standards, or the gentlest slope that fits the space.

Under the ADA a ramp run is limited by its rise, not its length.

On iLuvFreeTools, our sister site