Basket07399 358543

Homes and gardens/Stairs/Helical stair

Helical steel stair

A steel stair turning round a void, its stringers cut from flat plate and rolled to the helix, with oak treads and glass guarding following the curve.

Helical steel stair

3D modelFrom sample project FH12, rendered from the model.

What it is

A helical stair is set out by angle: every riser at its turn round the centre, the goings checked 270 mm in from each side as Approved Document K requires for tapered treads.

The stringers are developed flat so they can be cut from plate, and the guarding posts are set out by angle from the first riser.

Sizes and options

As we draw it. Every size is set to your job.

Sample4.0 m floor to floor, 24 risers of 166.7 mm, 280° of turn
StringersPlate, developed flat
TreadsSteel sectors with oak
GuardingGlass on stainless posts

Worth knowing

Tapered treads must all have the same going.

On a helical stair the going is measured on lines 270 mm in from each side, and consecutive tapered treads must use the same going. A stair with one tread a little wider fails, even if every tread is inside the limits.

Source: Approved Document K, 2013 edition, paragraph 1.26 and Diagram 1.9

The detail

How it is made, fitted and priced, and what to tell us.

The first fact is a count. Approved Document K limits a general access stair to 12 risers between landings, or 16 in small premises where plan area is restricted. A floor height of 4.2 m at a rise of 168 mm is 25 risers, and 24 would be 175 mm, over the 170 maximum. So an unbroken helix to that height fails the document as written, and the options are a landing in the turn, or an agreed variation with building control. Our sample is 12 risers up, a landing, then 12 more.

The second is the plan. Approved Document K sends helical stairs to BS 5395-2 and, for tapered treads on a stair 1 m or wider, measures the going on lines 270 mm in from each side. On our sample the goings are 252 mm on the inner line and 358 mm on the outer. Consecutive tapered treads must have the same going. The result is that the void has to be big: read literally for a 1200 mm wide stair, the inner radius needs to be at least 1177 mm. We have not read BS 5395-2 itself, which is paywalled, so building control has the final word on which route applies.

Making it is plate work. The stringers are cut from flat plate to a developed shape, rolled on edge and welded to the treads, and the whole stair is split into segments to get through the door and up in the lift. The splice at a riser line is either bolted behind the riser or welded on site and ground flush for the better finish. A slender steel stair of this size is usually governed by how it feels underfoot, not by strength, so the engineer checks vibration.

The cost levers are the stringer plate, the finish (paint or stainless), the treads and the guarding. Glass that follows the curve is made to the helix and is one of the larger items. Send us the void size, the floor to floor height, the finished levels and the door and lift sizes for delivery.

More views

Renders and sheets from our sample projects: made-up jobs, modelled and drawn the way a real one is.

Helical stair - view 1, rendered from the 3D model
3D renderSample project FH12
Helical stair - view 2, rendered from the 3D model
3D renderSample project FH12
FH12-AP-02 GA plan
FH12-AP-02GA plan

Is it right for you?

Good for

  • Atriums and receptions
  • Houses with a feature void

Not for

  • A tight budget: see the dog-leg

What the drawings show

  • Plan set out by angle, with every riser at its turn round the centre and the going at 270 mm in from each side
  • Developed inner and outer stringer elevations showing the plate cut shape and the post positions
  • A section through the void with the riser count, rise and headroom
  • The glass line, post by post, set out from riser 1
  • Segment splits and the site joints, with weights for the lift

Questions

Guide: Stair rules in England: rise, going, headroomGuide: How to measure for a balustrade or stair

How tight can a helical staircase be?

Approved Document K sets the going on lines 270 mm in from each side of a wide stair, not less than 250 mm on the inner line. For a 1200 mm wide stair that works out at an inner radius of at least 1177 mm, on our reading. A tighter stair is a spiral, not a helical, and BS 5395-2 applies.

Does a helical stair need a landing?

In a general access stair, yes, if it has more than 12 risers, or 16 in small premises. Private stairs in dwellings have no such limit. We check the riser count against the category when we set out the stair.

Which standard covers a helical stair?

Approved Document K says to design spiral and helical stairs in accordance with BS 5395-2, and still sends the going of tapered treads to its Diagram 1.9. Building control decides how the two are read together on your job, so it is worth asking them before the stair is drawn, not after.

How is a helical stair made?

From plate. Each stringer is developed flat, cut, rolled to the helix and welded to folded treads. The stair is cut into segments sized for the door and the lift, then joined on site at a riser line, either bolted or welded and ground flush. Your engineer designs it, including how it feels underfoot.

Can a helical stair taper to a point at the inside?

No. On a stair under 1 m wide the going is measured at the centre of the tread, and Approved Document K Diagram 1.9 asks for at least 50 mm of tread width at the narrow end. On a stair 1 m or wider, the going is measured on lines 270 mm in from each side instead.

Send the drawings.

Send the drawings and get a fixed price back within 4 working hours (Mon-Fri, 8 am-6 pm).

Not ready to send drawings? Ask for the full sample pack for your type of work, or a call back, with the form.

Big files: paste a WeTransfer, Dropbox or Google Drive link, or send them when we reply.

Thanks, that’s with us.

We use your details only to answer you: privacy, terms.