Basket07399 358543

Homes and gardens/Stairs/Escape stair balustrade

Escape stair balustrades

Balustrades and wall handrails up concrete escape stairs: the rail straight on every flight, raked up to 1100 mm past the nosing at each landing.

Escape stair balustrades

3D modelRendered from the model we draw from.

What it is

On a stair core the balustrade runs up the well side flight after flight. We keep the handrail straight on the rake and run it past the top nosing until it reaches the landing height, so there are no goosenecks.

Each flight is set out in its own elevation from its nosings, because a stair balustrade cannot be set out from a plan.

Sizes and options

As we draw it. Every size is set to your job.

PostsSHS 50, base plated to the flights
InfillBars or panels at less than 100 mm clear
Handrail900 to 1000 mm over the pitch line, 1100 mm on landings

Worth knowing

A stair can pass every rule but the pitch.

A private stair with a 220 mm rise and 220 mm going is inside the rise and going limits, and 2R + G is 660 mm, inside 550 to 700. But its pitch is 45 degrees, over the 42 degree maximum.

Source: Approved Document K, 2013 edition, Table 1.1

The detail

How it is made, fitted and priced, and what to tell us.

A stair core is set out flight by flight, never from a plan. A plan shows the balustrade as a line and cannot tell you where a post lands on the concrete, how far the plate is from the edge, or where the rail meets the landing height. We draw each flight in its own elevation from the nosings and the pitch line, with the first post pushed up the flight until its plate fits on the concrete. That is why a core with six flights has six elevations.

The numbers that govern are in Approved Document K. For buildings other than dwellings and the common areas of flats, a flight has no more than 12 risers if it is a general access stair and 16 if it is a utility stair, and the stair is at least 1200 mm wide between walls. Landings are at least 1200 mm long, a handrail goes on both sides of a stair 1000 mm wide or more, and each handrail extends 300 mm past the top and bottom nosings. Guarding is required where there are two or more risers.

Fixing into concrete is where jobs go wrong. On a raked flight our face-fixed plates take two M12 resin anchors; edge distance and cover to the nosing are checked on the model before the plates are cut. Resin anchors go in after the concrete, so a core drilled in the wrong place is a repair, not a revision. Where the concrete flights are by others, we ask for their drawings and a survey of the as-built nosings.

Part M also applies on stairs that form an access route, and where it conflicts with Part K, Part M takes precedence. Tell us the stair category, the number of flights and the building height, and send the concrete drawings.

More views

Renders and sheets from our sample projects: made-up jobs, modelled and drawn the way a real one is.

Escape stair balustrade - view 1, rendered from the 3D model
3D renderA real 3D model
Escape stair balustrade - view 2, rendered from the 3D model
3D renderA real 3D model
Escape stair balustrade - view 3, rendered from the 3D model
3D renderA real 3D model

Is it right for you?

Good for

  • Blocks of flats and offices
  • Stair cores of any height

What the drawings show

  • One elevation per flight, set out from the nosings, with every post and the rail line dimensioned
  • Each plate on its place on the concrete, with the distance to the edge and the anchor positions
  • The handrail's rake and its landing height, with the extension past each nosing
  • A landing sheet in plan showing the returns round the well
  • A parts list and marks for the posts, panels and plates

Questions

Guide: Balustrade heights in the UKGuide: Stair rules in England: rise, going, headroomGuide: How to measure for a balustrade or stair

What is the maximum number of steps in a flight?

For general access stairs in buildings other than dwellings, and common areas of flats, 12 risers, or 16 in small premises where plan area is restricted. Utility stairs may have 16. More than 36 risers needs a change of direction. Approved Document K paragraphs 1.17 and 1.18.

How high must stair balustrades be?

Guarding on a flight is 900 mm for all building types. On landings and floor edges it is 1100 mm in flats, offices and public buildings, and 900 mm in a single family dwelling. Handrails go 900 to 1000 mm above the pitch line. Approved Document K, Diagram 3.1 and paragraph 1.34.

Does an escape stair need a handrail both sides?

If it is 1000 mm wide or more, yes: Approved Document K asks for a handrail on both sides. Narrower stairs need one. It must be continuous along flights and landings and extend 300 mm past the top and bottom nosings.

Why can't the balustrade be set out from the plan?

A plan shows the posts in line but not their height on a rake, where the nosings are, or whether a plate fits on the concrete. The elevation off the nosings does. That is how we avoid a post landing on a nosing edge, and why a core of six flights has six elevations.

What gap is allowed between bars?

The infill must be built so a 100 mm sphere cannot pass, and ours is at less than 100 mm clear. Approved Document K paragraphs 1.39 and 3.3 apply that rule where the building may be used by children under five, so we draw it that way by default for flats and offices alike.

Your escape stair balustrade, drawn from a real 3D model.

Balustrade and stair design pack: from £249

Back in 3 working days or your money back. Or call 07399 358543 to ask first.