Steel feature stair

A steel dog-leg stair in a reception or atrium: plate stringers, a half landing, and a glass balustrade running round the well in one continuous line.

Steel feature stair

3D modelFrom sample project AS02, rendered from the model.

What it is

A feature stair is seen from every side, so the stringers, the landing frame and the glass channel are drawn to line through: the channel continuous, the glass made to fit the run rather than the other way round.

Across the well end the handrail runs flat, rakes at the flight pitch and runs flat again, so nothing kinks.

Sizes and options

As we draw it. Every size is set to your job.

StringersFL 250 plate
LandingPFC frame on SHS columns
GuardingGlass in a continuous base channel, slotted handrail

Worth knowing

A general access stair is limited to 12 risers between landings.

In buildings other than dwellings, and in the common parts of flats, a general access stair may have no more than 12 risers in a flight, or 16 in small premises where the plan area is restricted. That is why a floor-high reception stair often has a landing in the middle.

Source: Approved Document K, 2013 edition, paragraph 1.18b(ii)

The detail

How it is made, fitted and priced, and what to tell us.

The line you see is the glass channel and the handrail, so that is what the drawings set out first. On our sample stair the channel is one continuous line, and it breaks only where its bed steps. Across the well end the rail runs flat, rakes at the flight pitch and runs flat again. Where two beds meet at a corner the channel is mitred on the plan; where mitres would pass each other, one length runs through and the glass goes with it. We make the glass fit the run, not the run fit the glass.

The structure is deliberately plain. Plate stringers carry the flights, and a PFC frame on SHS columns carries the half landing. We keep each of those as one stock section, because the other trades box round them. The flight is welded in the shop and the tie to the floor is settled on the drawing, so the stair comes to site as large pieces and not as a kit. Your engineer designs the stair, including how it behaves underfoot; our drawings follow that design.

Approved Document K sets a limit that surprises people on a long run: a general access stair may have no more than 12 risers between landings, and exceptionally 16 in small premises. A reception stair of a full floor height almost always needs a half landing for that reason, and the landing is where the glass line has to turn. In a dwelling, the limits are looser: rise 150 to 220 and going 220 to 300, with a 42 degree maximum pitch.

What changes the price: the glass (number of panes, thickness, shape of the well), the finish (painted steel or stainless), the treads (steel, oak or stone) and the access for delivery. A curved or angled pane is a made piece. Send us the floor to floor height, the plan opening, the finished floor levels top and bottom, and what you want to see from below.

More views

Renders and sheets from our sample projects: made-up jobs, modelled and drawn the way a real one is.

Feature stair - view 1, rendered from the 3D model
3D renderA real 3D model

Is it right for you?

Good for

  • Offices, receptions and atriums
  • Houses with a double-height hall

Not for

  • A house stair on a budget: a standard timber or steel-and-timber stair costs less
  • A stair where no one will see the glass line: a bar balustrade is simpler

What the drawings show

  • The glass line in plan and elevation, with each pane's size and the gap to the next
  • The base channel set out from the nosings, with its joints and mitres marked
  • The half landing frame with its column fixings, in plan and section
  • The handrail heights over the pitch line and across the well, with the flat, rake and flat sections dimensioned
  • Stringer, tread and nosing details at the first and last risers

Questions

Guide: Balustrade heights in the UKGuide: Stair rules in England: rise, going, headroomGuide: How to measure for a balustrade or stair

Does a glass stair balustrade need a handrail?

Approved Document K asks for handrails at 900 to 1000 mm above the pitch line on stairs, and a handrail can form the top of the guarding if the heights match. A glass base channel with a slotted handrail on top is the usual way. Check with building control for your case.

How many steps can a stair have before a landing?

In buildings other than dwellings, a general access stair may have 12 risers between landings, or 16 in small premises where plan area is restricted. Utility stairs are limited to 16. Dwellings have no equivalent limit, but more than 36 risers needs a change of direction.

Can the stair be made in a workshop and carried in?

Yes, in pieces sized to the door and the lift. We split the stair at points the engineer agrees, usually at landings, and draw the site joints. The delivery route and weights go on the drawing.

What glass is used on a feature stair?

Toughened laminated glass, 21.5 mm on our sample, held in a base channel with a slotted handrail on top. Thicker or thinner builds depend on the tested system you choose. Section 5 of Approved Document K on glazing applies to glass in guarding.

What do you need from me for a feature stair?

A plan and section of the opening, the floor levels top and bottom, the fixing to the slab edge, and the look you want. A photo of a stair you like helps more than an adjective. If the slab edge is not yet built, send the engineer's drawing of it.

Your feature stair, drawn from a real 3D model.

Balustrade and stair design pack: from £395