Basket07399 358543

Tools/Stairs and ramps/ADA ramp slope calculator

ADA ramp slope calculator

Type the rise and either the slope or the length you have: the calculator splits the ramp into runs that each rise no more than the 2010 ADA Standards allow, adds the 60 in landings and checks the width, handrails and edges, for new work and for tight existing sites.

I have
2010 ADA Standards: the longest ramp run at each slope (405.2, 405.6, Table 405.2)
SlopeGradeLongest runRise
1:128.3%30′30″
1:137.7%32′ 6″30″
1:147.1%35′30″
1:156.7%37′ 6″30″
1:166.2%40′30″
1:175.9%42′ 6″30″
1:185.6%45′30″
1:195.3%47′ 6″30″
1:20 or gentler5.0%not a ramp (106.5)–
1:10 to 1:12–existing sites6″
1:8 to 1:10–existing sites3″

The calculator needs JavaScript, which is switched off or still loading. Everything else on this page reads without it.

Written for the United States, to the 2010 ADA Standards. Working to England's rules? Use the UK ramp gradient calculator.

Worth knowing

Under the ADA a ramp run is limited by its rise, not its length.

The 2010 ADA Standards cap a ramp's slope at 1:12 and each run's rise at 30 in (760 mm). The length follows from the slope: a 1:12 run may be 30 ft long, a 1:16 run 40 ft, before a 60 in landing. England's Approved Documents K and M work the other way round, from the length: a 1:12 flight may run only 2 m (6 ft 6 3/4 in), a 166 mm rise, and a flight 10 m long must be 1:20. A ramp laid out to one country's rule can fail the other's by a long way: the 30 ft run at 1:12 is more than four times what England allows at that slope.

Source: 2010 ADA Standards for Accessible Design, 405.2 and 405.6 (ada.gov); Approved Document K, 2013 edition, Diagram 2.1, and Approved Document M Volume 2, Table 1 (GOV.UK). Read on the page.

How it works

The arithmetic, the data it uses and where it stops.

Choose new construction or an existing site where space is tight. Type the total rise in inches (or feet and inches), then the slope as 1 in n, or the length you have. The ADA defines a ramp as a walking surface steeper than 1:20 (106.5); a slope of 1:20 or gentler is a walking surface, not a ramp.

Each run may rise 30 in at most (405.6) at a slope no steeper than 1:12 (405.2). The calculator divides the total rise into the fewest equal runs that each stay inside that, then adds a landing between each pair and one at the top and bottom, 60 in long (405.7.3); where the ramp turns at a landing it needs 60 x 60 in (405.7.4).

On an existing site where a 1:12 ramp will not fit, Table 405.2 allows short steeper runs: steeper than 1:12 up to 1:10 for a 6 in rise, steeper than 1:10 up to 1:8 for a 3 in rise. Steeper than 1:8 is not allowed. Choose the existing-site rule to see them.

Given a length instead of a slope, the calculator tries every whole slope the rule allows and gives the gentlest that fits with its landings. The table under the result lists them all with the longest run and the overall length.

The other checks: 36 in clear width, between the handrails where there are any (405.5); handrails on both sides of any run rising more than 6 in (405.8), 34 to 38 in high (505.4) and carried 12 in past the top and bottom of each run (505.10.1); a cross slope of 1:48 at most (405.3); edge protection at the sides of runs and landings (405.9). State and local codes, and the International Building Code where adopted, can add to these.

Questions

What is the maximum slope of an ADA ramp?

1:12, a rise of 1 in for every 12 in of run (405.2). On existing sites where space is tight, Table 405.2 allows 1:10 for a 6 in rise and 1:8 for a 3 in rise; steeper than 1:8 is prohibited.

How long can an ADA ramp run be?

As long as its rise stays at 30 in or less (405.6). At 1:12 that is 30 ft and at 1:16, 40 ft. Then a landing 60 in long.

When does an ADA ramp need handrails?

When a run rises more than 6 in (405.8): handrails on both sides, 34 to 38 in high (505.4), extended 12 in past the top and bottom of each run (505.10.1).

How wide must an ADA ramp be?

36 in clear, measured between the handrails where there are any (405.5). Landings are at least as wide as the widest run that reaches them (405.7.2).

How big is an ADA ramp landing?

60 in long at the top and bottom of every run (405.7.3), and 60 x 60 in where the ramp changes direction (405.7.4), level to 1:48.

More free tools

Calculators for buying, cutting and fitting steel.

UK

Steel weight calculator

UB, UC, PFC, angles, hot and cold hollow sections, bars and plate, from the BS EN tables. Build a list and get the total.

Hot-finished and cold-formed SHS do not weigh the same.
US

Steel weight per foot calculator

Every W, HP, S, C, MC, angle, HSS and pipe in the AISC Shapes Database, plus bar and plate, in pounds per foot.

An HSS weighs more than its listed area says.
Metric and imperial

Cutting list optimiser

Nest cut lengths into 6 m, 7.5 m, 20 ft or 24 ft bars with the saw cut allowed for, searched for the fewest bars.

Longest-first can buy a bar you do not need.
UK and US

Baluster spacing calculator

Equal gaps between posts under the 100 mm sphere (UK) or the 4 in sphere (US), with every bar set out.

On a stair, the UK and US rules part company.
Metric and imperial

Plate weight calculator

Rectangles, discs and rings with holes, in steel, stainless or aluminium: the weight to lift and the plate it is cut from.

A disc is 78.5% of the plate it is cut from.
Metric and imperial

Gate weight and hinge load calculator

The leaf weight from its frame and bars, the centre of gravity, and the pull on the top hinge.

The top hinge carries more than the gate weighs.
Metric and imperial

Bend allowance calculator

The flat blank for a folded part from its legs, angles and thickness, with the radius the die will really give and every bend line set out.

On a press brake the die sets the radius, not the drawing.
UK and US

Sheet metal gauge chart

Gauge to millimetres and back in the UK Standard Wire Gauge and the US steel, galvanized, stainless and aluminium tables, side by side.

16 gauge is five different thicknesses.
UK

Galvanising calculator

Vent and drain holes for sealed hollow sections, and the zinc a part picks up, to EN ISO 14713-2 and EN ISO 1461.

A sealed SHS 100 needs a 30 mm vent hole, not 10.
Metric and imperial

Fillet weld calculator

Leg and throat, weld metal per metre or foot, and the wire or electrodes to buy for the length, by process.

An a6 fillet is twice the weld of a z6.
UK

Bolt hole sizes

Normal, oversize and slotted holes for M12 to M30 bolts to EN 1090-2, with the minimum edge distances and spacings.

An M12 hole is 13 mm, not 14.
US

Bolt hole size chart

Standard, oversized and slotted holes for 1/2 in to 1 1/2 in structural bolts, from RCSC Table 3.1, with the washers they call for.

The 1/16 in rule stops at 7/8 in.
UK

Steel paint calculator

Paint or powder for a list of UK sections: the area from the Blue Book tables, then litres or kilograms by coats and method.

A tonne of steel can be 2.2 m² of paint, or 68.
UK

Stair calculator

Risers, going, pitch and 2R + G for a floor-to-floor height, the flights and landings, the stairwell opening and the handrails, checked against Approved Document K.

At a 220 mm rise, a private stair's going has 16 mm of room.
UK

Spiral and curved stair calculator

Treads a turn, the going on the line it is measured on, the narrow end and the headroom under the turn above, for spiral, helical and curved stairs.

Under 1 m wide, a tapered tread is measured on its centre line.
UK

Ramp gradient calculator

Flights, landings and overall length for a ramp of any rise, checked against Approved Documents M and K, or the gentlest gradient that fits the space.

At 1:12 a ramp flight may run only 2 m.
UK

Balustrade height checker

The guarding height for the building and the place, whether guarding is needed at that drop, and the 100 mm sphere, from Approved Document K.

The 600 mm rule is for homes only.
Metric and imperial

Post hole concrete calculator

Concrete for fence and gate posts: the hole less the post, in litres and 20 kg bags of Postcrete or concrete mix, with the hole checked against the makers' guidance.

Postcrete is for gates under 1 m wide.
Metric and imperial

Tap drill size chart

The drill for every metric coarse and fine thread from M1.6 to M42, for cutting and forming taps, with the thread depth it leaves.

A forming tap needs a bigger hole than a cutting tap.
Metric and imperial

mm to inches converter

Millimetres to inch fractions to 1/64, feet and inches, kilograms to pounds, and a chain of dimensions converted without the rounding creeping.

Round the running total, not each dimension.
UK

Steel cost calculator

Price a list of sections by the stock bars you will actually buy: nested section by section with the saw cut, at your price a kilogram, with the extras.

You pay for the bar, not the piece.

On iLuvFreeTools, our sister site